文献速递关节外科

陶瓷-金属轴承全髋关节置换术后血清离子水平升高:亚洲生活方式的影响

Increased Serum Ion Levels After Ceramic-on-Metal Bearing Total Hip Arthroplasty: Influence of an Asian Lifestyle.
PubMed 文献 · J Arthroplasty · 2017-10-26

该研究测量了201例(234髋)患者的血清金属离子水平,其中121例COM全髋关节置换(140髋)与80例非COM(94髋)对照。COM组钴(1.86 ± 4.0 μg/L)和铬(1.81 ± 2.87 μg/L)显著高于非COM组(钴0.27 ± 0.14 μg/L;铬0.19 ± 0.25 μg/L;P < .001)。能完成蹲位和跪位的患者金属离子水平更高,COM组离子水平与总活动度相关。

要点

  • COM全髋关节置换患者中期随访血清钴和铬水平显著高于非COM患者。
  • 能完成蹲位和跪位的COM患者血清金属离子水平更高。
  • COM组金属离子水平与总活动度相关,活动度大者风险更高。

核心结论

  • 36-mm陶瓷-金属轴承全髋关节置换患者中期随访临床结果良好,但血清金属水平高。
  • 能完成更大活动度、蹲位和跪位的COM全髋关节置换患者存在金属离子相关问题的风险。

研究设计与样本

  • 研究测量了201例患者(234髋)的血清金属水平,包括121例COM患者(140髋)和80例非COM患者(94髋)。
  • 研究评估了Harris髋关节评分、加州大学洛杉矶分校活动量表评分和西安大略和麦克马斯特大学骨关节炎指数评分,并获取X线片进行分析。

主要发现

  • COM全髋关节置换组血清钴为1.86 ± 4.0 μg/L、铬为1.81 ± 2.87 μg/L,非COM组钴为0.27 ± 0.14 μg/L、铬为0.19 ± 0.25 μg/L,组间差异P < .001。
  • 能完成蹲位患者的血清金属水平显著高于不能蹲位者(钴P = .033;铬P = .074)。
  • 能完成跪位患者的血清金属水平显著高于不能跪位者(钴P = .049;铬P = .031)。
  • COM组金属离子水平与总活动度相关(钴P = .0293;铬P = .0399)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Recent clinical studies have suggested that systemic metal ion levels are significantly elevated at midterm follow-up in patients with ceramic-on-metal (COM) bearing. However, it is not clear whether there is a correlation between patient-related factors including the lifestyle and elevated levels of serum metal ions following COM total hip arthroplasty (THA). METHODS: Serum metal levels were measured in 201 patients (234 hips) including 121 COM patients (140 hips) and 80 non-COM patients (94 hips). The Harris Hip Score, University of California, Los Angeles activity scale score, and Western Ontario and McMaster Universities Osteoarthritis Index score were measured and radiographs were obtained for the analysis. RESULTS: Significantly higher levels of cobalt (Co) and chromium (Cr) were detected in the serum of the COM THA group (Co: 1.86 ± 4.0 μg/L; Cr: 1.81 ± 2.87 μg/L) than those of the non-COM THA group (Co: 0.27 ± 0.14 μg/L; Cr: 0.19 ± 0.25 μg/L; P < .001). The serum metal levels of patients who achieved the squatting position and the kneeling position were significantly higher than those of patients who could not squat (Co: P = .033; Cr: P = .074) and kneel (Co: P = .049; Cr: P = .031). The metal ion levels of the COM THA group correlated with the total range of motion (Co: P = .0293; Cr: P = .0399). CONCLUSION: Patients who underwent a 36-mm COM THA showed high serum metal levels although good clinical outcomes at the midterm follow-up. We found that COM THA patients who were capable of greater range of motion, squatting, and kneeling are at risk of metal ion-related problems.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Han SB, Oh JK, Jang WY, et al. Increased Serum Ion Levels After Ceramic-on-Metal Bearing Total Hip Arthroplasty: Influence of an Asian Lifestyle. J Arthroplasty. 2017. PMID: 29174760. doi:10.1016/j.arth.2017.10.037

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。