文献速递关节外科

股骨柄设计对前路全髋关节置换术后失败的影响

Impact of Femoral Stem Design on Failure After Anterior Approach Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-11-11

回顾性分析2名术者连续1120例直接前路全髋关节置换术,899例(80.3%)获2年随访。90天内并发症20例(1.8%),翻修9例(1%),其中无菌性股骨松动5例(0.55%)。带领全羟基磷灰石涂层压实扩髓柄或三锥度近端匹配填充柄无因无菌性松动翻修,锥形楔形柄翻修率显著高于羟基磷灰石涂层压实扩髓柄(P < .005)。

要点

  • 899例随访2年,无菌性股骨松动翻修率0.55%。
  • 带领全HA涂层或三锥度近端匹配填充柄无无菌性松动翻修。
  • 锥形楔形柄股骨松动翻修率显著高于HA涂层压实扩髓柄(P < .005)。

核心结论

  • 疼痛和功能可预期改善,2年随访股骨松动率为0.55%。
  • 带领全HA涂层和三锥度匹配填充股骨柄无因无菌性松动翻修,而短柄无领内侧-外侧锥形组有3例。

研究设计与样本

  • 回顾性 review,纳入2名术者初始连续1120例直接前路全髋关节置换术患者。

主要发现

  • 899例(80.3%)获2年随访(范围2-8年)。
  • 90天内并发症20例(1.8%):股骨距骨折10例、大转子骨折1例、髓腔穿孔1例、血肿3例、脱位2例、表浅感染2例、深部感染1例。
  • 翻修9例(1%):无菌性股骨松动5例(0.55%)、假体周围关节感染1例、脱位1例、髋屈肌刺激1例、聚乙烯衬垫损坏1例。
  • 5例无菌性股骨松动中,3例为短的内侧-外侧锥形柄,1例为骨水泥柄,1例为S-ROM柄用于绕过髓腔穿孔。
  • 带领全HA涂层压实扩髓柄或三锥度近端匹配填充柄设计(占所有柄的70.6%)无因无菌性松动翻修。

关键数值与推荐

  • 无菌性股骨松动翻修率0.55%(5/899)。
  • 锥形楔形柄与HA涂层压实扩髓柄的股骨松动翻修率比较,P < .005。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: An increased rate of complications related to femoral component failure has been described with less invasive total hip arthroplasty (THA). This study evaluated the incidence of femoral complications associated with the direct anterior approach for THA. METHODS: Retrospective review was performed of the initial 1120 consecutive patients who underwent direct anterior THA by 2 surgeons. RESULTS: A total of 899 patients (80.3%) had a 2-year follow-up (range, 2-8 years). Complications within 90 days occurred in 20 patients (1.8%): 10 calcar fractures, 1 greater trochanter fracture, 1 canal perforation, 3 hematomas, 2 dislocations, 2 superficial, and 1 deep infection. Nine patients (1%) underwent revision: 5 for aseptic femoral loosening (0.55%), 1 for periprosthetic joint infection, 1 for dislocation, 1 for hip flexor irritation, and 1 for a damaged polyethylene liner. Of the 5 patients with aseptic femoral loosening, 3 had a short, mediolateral tapered stem, 1 cemented stem, and 1 S-ROM stem placed to bypass a canal perforation. There were no revisions for aseptic loosening in the collared, fully hydroxyapatite (HA)-coated compaction broached or triple tapered proximal fit and fill stem designs (70.6% of all stems). Revision rate for femoral loosening was significantly higher for tapered wedge over HA-coated, compaction broached stems (P < .005). CONCLUSION: Pain and function improved predictably with a 0.55% rate of femoral loosening at 2-year follow-up. Among collared, fully HA-coated and triple taper fit and fill femoral stems, there were no instances of revision for aseptic loosening vs 3 in the short stem, collarless mediolateral tapered group.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Cidambi KR, Barnett SL, Mallette PR, et al. Impact of Femoral Stem Design on Failure After Anterior Approach Total Hip Arthroplasty. J Arthroplasty. 2017. PMID: 29137901. doi:10.1016/j.arth.2017.10.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。