旋转铰链假体用于复杂初次与翻修全膝关节置换术
本研究基于前瞻性维护的手术数据库,纳入79膝(复杂初次14膝、翻修65膝)使用单一设计旋转铰链膝假体,平均随访55.2个月,膝关节协会评分从35.7分改善至66.2分(P<.01),并发症发生率为38.7%,5年估计生存率为70.7%。
要点
- 旋转铰链膝假体用于复杂初次与翻修全膝关节置换,平均随访55.2个月时膝关节协会评分从35.7分改善至66.2分(P<.01)。
- 并发症发生率为38.7%,最常见为假体周围骨折、伸膝装置断裂和假体周围感染。
- 5年估计生存率为70.7%,无菌性松动罕见,但假体周围骨折、感染和伸膝装置失效较多。
核心结论
- 尽管设计和生物材料有所改进,现代旋转铰链膝假体仍伴随相对较高的并发症发生率。
- 无菌性松动罕见,但假体周围骨折、感染和伸膝装置失效较多,凸显了这些病例的复杂性。
研究设计与样本
- 使用前瞻性维护的手术数据库,纳入79膝(76例患者)接受单一设计旋转铰链膝假体,其中复杂初次全膝关节置换14膝、翻修全膝关节置换65膝。
- 队列包括60例女性和16例男性,手术时平均年龄66.7岁(范围39-89岁)。
- 19%因假体周围感染接受旋转铰链膝假体,32.9%同时行伸膝装置修复。
- 采用膝关节协会评分评估患者结局,并通过X线片审查磨损和松动迹象,使用Kaplan-Meier生存曲线估计失败率。
主要发现
- 至少随访2年时,13例患者死亡、4例失访,剩余59例患者62膝,平均随访55.2个月(范围24-146个月)。
- 平均膝关节协会评分从35.7分改善至66.2分(P<.01)。
- 并发症发生率为38.7%,最常见并发症为假体周围骨折、伸膝装置断裂和假体周围感染。
- 5年估计生存率为70.7%。
关键数值与推荐
- 平均膝关节协会评分从35.7分改善至66.2分(P<.01)。
- 并发症发生率为38.7%。
- 5年估计生存率为70.7%。
局限性
- 至少随访2年时,13例患者死亡、4例失访,剩余59例患者62膝完成随访。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Contemporary rotating hinge knee (RHK) prosthesis has shown improved survival rates over earlier generations. However, reports of high complication and mechanical failure rates highlight the need for more clinical outcome data in the complex primary and revision setting. The purpose of this study is to report our results of using a contemporary rotating hinge for complex primary and revision total knee arthroplasty. METHODS: Using a prospectively maintained surgical database, 79 knees in 76 patients who underwent an RHK of a single design for either a complex primary (14 knees) or revision total knee arthroplasty (65 knees) were identified. This included 19% undergoing an RHK for periprosthetic joint infection and 32.9% who had concomitant extensor mechanism repair. The cohort consisted of 60 women and 16 men with a mean age of 66.7 years (range 39-89) at the time of surgery. Patient outcomes were assessed using Knee Society Scores and radiographs were reviewed for signs of wear and loosening. Failure rates were estimated using Kaplan-Meier survival curves. RESULTS: At a minimum of 2 years, 13 patients had died and 4 were lost to follow-up, leaving 62 knees in 59 patients who were followed for a mean of 55.2 months (range 24-146). The mean Knee Society Scores improved from 35.7 to 66.2 points (P < .01). The incidence of complications was 38.7%. The most common complications were periprosthetic fracture, extensor mechanism rupture, and periprosthetic infection. Estimated survival was 70.7% at 5 years. CONCLUSION: Despite improvements in design and biomaterials, there remains a relatively high complication rate associated with the use of a modern RHK implant. While aseptic loosening was rare, periprosthetic fracture, infection, and extensor mechanism failure were substantial emphasizing the complex nature of these cases.
引用
- Kearns SM, Culp BM, Bohl DD, et al. Rotating Hinge Implants for Complex Primary and Revision Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 29129618. doi:10.1016/j.arth.2017.10.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。