人工髋关节置换术前后的骨盆倾斜位移
本研究评估了355例因发育性髋关节发育不良继发骨关节炎行全髋关节置换术(THA)的患者,基于术前和术后第1天CT图像分析对侧关节状况对骨盆位移的影响。对侧关节间隙≥2mm组(W组)位移方差显著高于间隙<2mm组(N组),对侧关节状况影响骨盆位移。
要点
- 对侧关节间隙宽(≥2mm)时骨盆位移方差较高。
- 对侧关节状况影响THA术后骨盆位移。
- 组间方差差异有统计学意义(P = .0001)。
核心结论
- 对侧关节间隙宽时骨盆位移方差较高,对侧关节影响骨盆位移。
研究设计与样本
- 共评估355例因发育性髋关节发育不良继发骨关节炎行全髋关节置换术(THA)的患者,术前和术后第1天行CT检查。
- 骨盆平面基于术前和术后第1天CT图像确定,前倾方向位移以+表示。
- 对侧髋关节最小关节间隙<2mm者为N组,≥2mm者为W组,已行THA者为P组,同期双侧THA者为B组。
- 组间等方差检验采用Bartlett检验,两两比较采用F检验,P值<.01认为有统计学意义。
主要发现
- N组49例,位移为-0.2° ± 2.7°;W组227例,位移为0.8° ± 3.9°;P组55例,位移为0.5° ± 2.6°;B组24例,位移为1.1° ± 4.0°。
- 组间方差差异有统计学意义(P = .0001)。
- W组与N组差异有统计学意义(P = .0020)。
- W组与P组差异有统计学意义(P = .0003)。
- P组与B组差异有统计学意义(P = .0086)。
关键数值与推荐
- 对侧髋关节最小关节间隙<2mm为N组,≥2mm为W组,已行THA为P组,同期双侧THA为B组。
- P值<.01认为有统计学意义。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Prediction of pelvic displacement before total hip arthroplasty (THA) is important for accurate acetabular implant placement. This study aimed to evaluate the effect of contralateral joint conditions on pelvic displacement after THA. METHODS: A total of 355 cases that underwent computed tomography before and after THA for osteoarthritis due to developmental dysplasia were assessed. The pelvic plane was based on preoperative and postoperative day 1 computed tomography images. The displacement in the anteversion direction was expressed as +. Subjects with a minimal joint space <2 mm in the contralateral hip joint were in group N; subjects with ≥2 mm were in group W; subjects with THA were in group P; and subjects who underwent THA simultaneously on both sides were in group B. The Bartlett test was used when conducting the equal variance test among the groups. The F test was used for pairwise comparison. A P value <.01 was considered statistically significant. RESULTS: Groups N, W, P, and B had 49, 227, 55, and 24 cases, respectively, and their displacements were -0.2° ± 2.7°, 0.8° ± 3.9°, 0.5° ± 2.6°, and 1.1° ± 4.0°, respectively; the variance between the groups was significantly different (P = .0001). The differences between groups W and N (P = .0020), between groups W and P (P = .0003), and between groups P and B (P = .0086) were statistically significant. CONCLUSION: When the contralateral joint space is wide, the variance of the displacement is high. The contralateral joint affects pelvic displacement.
引用
- Nishiwaki T, Hata R, Oya A, et al. Pelvic Tilt Displacement Before and After Artificial Hip Joint Replacement Surgery. J Arthroplasty. 2017. PMID: 29122388. doi:10.1016/j.arth.2017.10.014