腘绳肌腱移植物在隧道内的长度对移植物整合的影响
这项前瞻性队列研究纳入62例前交叉韧带重建患者,比较四股半腱肌腱(ST4)与半腱肌腱+股薄肌腱(STG)移植物的整合情况。术后1年MRI显示两组在信噪比、胫骨隧道扩大、骨-移植物界面信号及Howell量表评分上均无显著差异,ST4的整合与韧带化至少不劣于标准STG。
要点
- 术后1年MRI显示ST4与STG移植物的整合和韧带化相同。
- ST4组平均信噪比5.9±3.7,STG组5.2±4.5(P=.5100)。
- 胫骨隧道扩大STG组93.7%±51.7% vs ST4组80.0%±42.9%(P=.2605)。
核心结论
- 术后1年随访时,基于MRI分析,STG与ST4移植物的整合和韧带化相同。
- 在整合和韧带化方面,ST4技术的结果至少与标准STG技术一样好。
研究设计与样本
- 前瞻性队列研究,证据等级2。
- 纳入62例接受前交叉韧带重建的患者:ST4组31例,STG组31例。
- 两组采用相同的手术技术、固定方法和术后方案。
- 术后1年随访时用MRI评估移植物整合和韧带化。
- 显示两种技术平均信噪比无差异所需样本量为每组31例(单侧α为2.5%,单侧β为10.0%)。
主要发现
- 平均信噪比STG组为5.2±4.5,ST4组为5.9±3.7(P=.5100)。
- 平均胫骨隧道扩大STG组为93.7%±51.7%,ST4组为80.0%±42.9%(P=.2605)。
- 两组在骨-移植物界面信号强度上无差异(P=.7502)。
- 两组在Howell量表移植物信号上无差异(P=.4544)。
关键数值与推荐
- 评估参数包括信噪比、胫骨隧道扩大、骨-移植物界面信号强度及Howell量表移植物信号。
- 连续次要终点分布的比较采用Student t检验。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Anterior cruciate ligament (ACL) reconstruction with a quadrupled semitendinosus (ST4) graft is an evolution of the standard technique with 2 hamstring tendons (semitendinosus + gracilis [STG]). However, there is no published comparison of how well these 2 types of hamstring grafts are incorporated into the bone tunnels. Because the ST4 graft is shorter, there is less graft material inside the tunnels. PURPOSE: To use magnetic resonance imaging (MRI) to compare graft incorporation in the tibial bone tunnels 1 year after ACL reconstruction with either an STG graft or ST4 graft. STUDY DESIGN: Cohort study; Level of evidence, 2. METHODS: Sixty-two patients who underwent ACL reconstruction were enrolled prospectively: 31 with an ST4 graft and 31 with an STG graft. The same surgical technique, fixation method, and postoperative protocol were used in both groups. Graft incorporation and ligamentization were evaluated with MRI after 1 year of follow-up. The following parameters were evaluated: signal-to-noise quotient (SNQ), tibial tunnel enlargement, signal intensity at the bone-graft interface, and graft signal according to the Howell scale. The number of participants needed to show that the mean SNQ did not differ between the 2 techniques was 31 in each group (with a 1-sided alpha of 2.5% and a 1-sided beta of 10.0%). The Student t test was used to compare the distribution of continuous secondary endpoints. RESULTS: The mean SNQ was 5.2 ± 4.5 for the STG group and 5.9 ± 3.7 for the ST4 group ( P = .5100). The mean tibial tunnel widening was 93.7% ± 51.7% for the STG group versus 80.0% ± 42.9% for the ST4 group ( P = .2605). The groups did not differ in signal intensity at the bone-graft interface ( P = .7502) or in graft signal according to the Howell scale ( P = .4544). CONCLUSION: At the 1-year postoperative follow-up, incorporation and ligamentization of the STG and ST4 grafts were the same based on MRI analysis. The results were at least as good with the ST4 technique as with the standard STG technique in terms of incorporation and ligamentization.
引用
- Cavaignac E, Marot V, Faruch M, et al. Hamstring Graft Incorporation According to the Length of the Graft Inside Tunnels. Am J Sports Med. 2017. PMID: 29065271. doi:10.1177/0363546517733472
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。