运动学对线全膝关节置换术后,内翻或外翻离群者的内外侧间室受力是否高于对线在范围内者?运动学对线全膝关节置换术后的下肢与关节线对线
在67例接受运动学对线全膝关节置换术的患者中,术中测量内侧与外侧间室受力,并按机械对线标准将术后对线分为内翻或外翻离群与在范围内。多数对线指标的内翻或外翻离群者与在范围内者的间室受力无差异,仅胫股角内翻离群者外侧间室平均反常受力比在范围内者高6磅;无任何对线指标可预测间室受力。
要点
- 按机械对线标准,运动学对线全膝关节置换术后各对线指标的内翻或外翻离群比例较高。
- 除胫股角内翻离群者外侧间室平均反常受力比在范围内者高6磅外,其余对线离群者与在范围内者间室受力无差异。
- 下肢、膝关节及假体对线指标均不能预测内侧或外侧间室受力。
核心结论
- 尽管运动学对线全膝关节置换术按机械对线标准有较高比例的内翻或外翻离群,但对线离群者术中内侧与外侧间室受力与在范围内者相当,无内侧或外侧间室过载的证据。
研究设计与样本
- 在67例接受运动学对线全膝关节置换术的患者中,于被动活动时用带传感器的胫骨垫片测量内侧与外侧间室术中受力。
- 以完全伸直、屈曲45°和屈曲90°三个角度受力的均值确定内侧与外侧间室受力。
- 对线测量包括下肢与假体的髋-膝-踝角(HKA)、胫骨近端内侧角(PMTA)、股骨远端外侧角(DLFA),以及膝关节与假体的胫股角(TFA)、胫骨假体角(TCA)、股骨假体角(FCA)。
- 对线在术后非负重前后位(AP)扫描片上测量,并按机械对线标准分为内翻或外翻离群与在范围内。
主要发现
- 内翻或外翻离群的比例分别为:HKA角16%/24%,PMTA 55%/0%,DLFA 0%/57%,TFA 25%/12%,TCA 100%/0%,FCA 0%/64%。
- 总体上,对线离群者内侧与外侧间室受力与在范围内者无差异。
- 仅TFA内翻离群者外侧间室平均反常受力比在范围内者高6磅。
- 下肢、膝关节及假体对线指标均不能预测内侧或外侧间室受力。
关键数值与推荐
- 内翻或外翻离群的比例分别为:HKA角16%/24%,PMTA 55%/0%,DLFA 0%/57%,TFA 25%/12%,TCA 100%/0%,FCA 0%/64%。
- TFA内翻离群者外侧间室平均反常受力比在范围内者高6磅。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aims of this study were to determine the proportion of patients with outlier varus or valgus alignment in kinematically aligned total knee arthroplasty (TKA), whether those with outlier varus or valgus alignment have higher forces in the medial or lateral compartments of the knee than those with in-range alignment and whether measurements of the alignment of the limb, knee and components predict compartment forces. PATIENTS AND METHODS: The intra-operative forces in the medial and lateral compartments were measured with an instrumented tibial insert in 67 patients who underwent a kinematically aligned TKA during passive movement. The mean of the forces at full extension, 45° and 90° of flexion determined the force in the medial and lateral compartments. Measurements of the alignment of the limb and the components included the hip-knee-ankle (HKA) angle, proximal medial tibial angle (PMTA), and distal lateral femoral angle (DLFA). Measurements of the alignment of the knee and the components included the tibiofemoral angle (TFA), tibial component angle (TCA) and femoral component angle (FCA). Alignment was measured on post-operative, non-weight-bearing anteroposterior (AP) scanograms and categorised as varus or valgus outlier or in-range in relation to mechanically aligned criteria. RESULTS: The proportion of patients with outlier varus or valgus alignment was 16%/24% for the HKA angle, 55%/0% for the PMTA, 0%/57% for the DLFA, 25%/12% for the TFA, 100%/0% for the TCA, and 0%/64% for the FCA. In general, the forces in the medial and lateral compartments of those with outlier alignment were not different from those with in-range alignment except for the TFA, in which patients with outlier varus alignment had a mean paradoxical force which was 6 lb higher in the lateral compartment than those with in-range alignment. None of the measurements of alignment of the limb, knee and components predicted the force in the medial or lateral compartment. CONCLUSION: Although kinematically aligned TKA has a high proportion of varus or valgus outliers using mechanically aligned criteria, the intra-operative forces in the medial and lateral compartments of patients with outlier alignment were comparable with those with in-range alignment, with no evidence of overload of the medial or lateral compartment of the knee. Cite this article: Bone Joint J 2017;99-B:1319-28.
引用
- Shelton TJ, Nedopil AJ, Howell SM, et al. Do varus or valgus outliers have higher forces in the medial or lateral compartments than those which are in-range after a kinematically aligned total knee arthroplasty? limb and joint line alignment after kinematically aligned total knee arthroplasty. Bone Joint J. 2017. PMID: 28963153. doi:10.1302/0301-620X.99B10.BJJ-2017-0066.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。