文献速递关节外科

全膝关节置换术中基于加速度计和计算机辅助导航:机械轴离群值减少但功能结局或生活质量未优于传统全膝关节置换术

Accelerometer-Based and Computer-Assisted Navigation in Total Knee Arthroplasty: A Reduction in Mechanical Axis Outliers Does Not Lead to Improvement in Functional Outcomes or Quality of Life When Compared to Conventional Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-09-14

前瞻性匹配研究比较全膝关节置换术中基于加速度计导航(ABN)、计算机辅助手术(CAS)与传统器械(CON)的临床结局。ABN和CAS组机械轴、股骨和胫骨假体对线显著优于CON组,机械轴离群值显著减少,但2年随访时三组功能结局、生活质量或满意度无显著差异。ABN手术时间显著短于CAS但与CON相似。

要点

  • ABN和CAS组机械轴、股骨和胫骨假体对线显著优于CON组,机械轴离群值显著减少(P = .034)。
  • ABN手术时间(83.9 ± 21 min)显著短于CAS(101 ± 11 min;P < .001),与CON(76.6 ± 17 min)相似(P = .131)。
  • 2年随访时三组功能结局、生活质量或满意度无显著差异(P > .05)。

核心结论

  • ABN骨切割精度与CAS相当且手术时间与CON相似,但在全膝关节置换术后2年随访中未显示任何临床结局优势。

研究设计与样本

  • 前瞻性匹配研究,2013年7月至2014年4月连续纳入152例患者(152膝)行全膝关节置换术,ABN组38例、CAS组38例、CON组76例。
  • 按年龄、性别、体重指数、术前活动度、膝关节学会评分、牛津膝关节评分、短表36生理和心理成分评分及术前畸形以1:1:2比例进行前瞻性匹配。
  • 所有患者前瞻性随访2年。

主要发现

  • ABN和CAS组机械轴(P = .018)、股骨(P = .050)和胫骨假体对线(P = .008)显著优于CON组。
  • ABN和CAS组机械轴离群值显著少于CON组(P = .034)。
  • ABN组手术时间(83.9 ± 21 min)显著短于CAS组(101 ± 11 min;P < .001),与CON组(76.6 ± 17 min)相似(P = .131)。
  • 2年随访时三组功能结局、生活质量指标或满意度无显著差异(P > .05)。

关键数值与推荐

  • ABN和CAS组机械轴、股骨和胫骨假体对线显著优于CON组(P = .018、P = .050、P = .008)。
  • ABN和CAS组机械轴离群值显著少于CON组(P = .034)。
  • ABN组手术时间83.9 ± 21 min vs CAS组101 ± 11 min(P < .001)vs CON组76.6 ± 17 min(P = .131)。
  • 2年随访时三组功能结局、生活质量或满意度无显著差异(P > .05)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Accelerometer-based navigation (ABN) is a novel navigation system that attempts to combine the accuracy of computer-assisted surgery (CAS) with the familiarity of conventional instrumentation (CON). No studies have compared the clinical outcomes of this new technology with existing techniques to date. METHODS: From July 2013 to April 2014, 152 consecutive patients (152 knees) underwent total knee arthroplasty using ABN (n = 38), CAS (n = 38), or CON (n = 76). We prospectively matched the groups in a 1:1:2 ratio for age, gender, body mass index, preoperative range of motion, Knee Society Score, Oxford Knee Score, Short-Form 36 Physical and Mental Component Scores, and preoperative deformity using preoperative data in isolation, thus controlling for potential confounding factors. All patients were prospectively followed for 2 years. RESULTS: The ABN and CAS groups had a significantly improved mean mechanical axis (P = .018), femoral (P = .050) and tibial component alignment (P = .008) compared to the CON group. There were significantly less mechanical axis outliers in the ABN and CAS groups (P = .034). The duration of surgery for the ABN group (83.9 ± 21 min) was significantly shorter than the CAS group (101 ± 11 min; P < .001) but similar to the CON group (76.6 ± 17 min; P = .131). There was no significant difference in functional outcomes, quality of life measures or satisfaction rates between the 3 groups at 2 years (P > .05). CONCLUSION: Although bone cuts were as accurate as CAS and operation time was similar to CON, the use of ABN failed to demonstrate any advantages in clinical outcomes following total knee arthroplasty at 2 years follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Goh GS, Liow MHL, Tay DK, et al. Accelerometer-Based and Computer-Assisted Navigation in Total Knee Arthroplasty: A Reduction in Mechanical Axis Outliers Does Not Lead to Improvement in Functional Outcomes or Quality of Life When Compared to Conventional Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 29054725. doi:10.1016/j.arth.2017.09.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。