高交联聚乙烯减少全髋关节置换术的磨损和翻修率:一项10年双盲随机对照试验

Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty: A 10-Year Double-Blinded Randomized Controlled Trial.
PubMed 文献 · J Bone Joint Surg Am · 2017-01-01

这项前瞻性双盲随机对照试验将122例患者随机分配至传统超高分子量聚乙烯内衬组或高交联聚乙烯内衬组,至少随访10年。高交联聚乙烯组三维磨损率、骨溶解患病率和翻修率均显著低于传统聚乙烯组,而两组临床评分无显著差异。

要点

  • 高交联聚乙烯组三维磨损率均值0.03 mm/年,显著低于传统聚乙烯组的0.27 mm/年(p < 0.001)。
  • 高交联聚乙烯组骨溶解患病率8%,显著低于传统聚乙烯组的38%(p < 0.005)。
  • 高交联聚乙烯组翻修率1.9%,显著低于传统聚乙烯组的14.6%(p = 0.012),12例翻修中10例在传统聚乙烯组。

核心结论

  • 高交联聚乙烯内衬显著减少了磨损,并且与10年时更高的假体生存率相关。

研究设计与样本

  • 前瞻性双盲随机对照试验,将122例患者随机分配至传统超高分子量聚乙烯内衬组(Enduron;DePuy)或高交联聚乙烯内衬组(Marathon;DePuy)。
  • 91例患者在至少10年(范围10.08至12.17年)时接受了临床和影像学评估,收集了牛津髋关节评分和短表-12健康调查评分。
  • 影像学使用经验证的软件分析骨溶解以及二维、三维和体积磨损。

主要发现

  • 10年随访时所有122例患者均有记录:12例接受了翻修手术,21例死亡(其中1例曾接受翻修手术),2例无法返回随访,91例可进行临床和影像学评估。
  • 至少10年时,高交联聚乙烯组三维磨损率均值0.03 mm/年,显著低于传统超高分子量聚乙烯组的均值0.27 mm/年(p < 0.001)。
  • 高交联聚乙烯组骨溶解患病率为8%,显著低于传统超高分子量聚乙烯组的38%(p < 0.005)。
  • 高交联聚乙烯组翻修率为1.9%,显著低于传统超高分子量聚乙烯组的14.6%(p = 0.012),12例翻修中10例在Enduron组。
  • 两组临床评分无显著差异。

关键数值与推荐

  • 三维磨损率:高交联聚乙烯组均值0.03 mm/年 vs 传统超高分子量聚乙烯组均值0.27 mm/年(p < 0.001)。
  • 骨溶解患病率:高交联聚乙烯组8% vs 传统超高分子量聚乙烯组38%(p < 0.005)。
  • 翻修率:高交联聚乙烯组1.9% vs 传统超高分子量聚乙烯组14.6%(p = 0.012)。
  • 证据等级:治疗性I级。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Highly cross-linked polyethylene (XLPE) was developed to address the problem of wear and osteolysis associated with metal-on-conventional ultra-high molecular weight polyethylene (UHMWPE) bearing surfaces. The purpose of this study was to compare in vivo wear rates and clinical and radiographic outcomes between XLPE and UHMWPE in a prospective double-blinded randomized controlled trial with a minimum of 10 years of follow-up. METHODS: We randomized 122 patients to receive either a conventional UHMWPE liner (Enduron; DePuy) or an XLPE liner (Marathon; DePuy). Ninety-one patients were assessed clinically and radiographically at a minimum of 10 years (range, 10.08 to 12.17 years). Oxford Hip Scores and Short Form-12 Health Survey scores were collected. The radiographs were analyzed for osteolysis and for 2-dimensional (2-D), 3-dimensional (3-D), and volumetric wear using validated software. RESULTS: All 122 patients were accounted for at the 10-year follow-up evaluation. Twelve patients had undergone revision surgery, 21 patients had died (1 of whom had previously undergone revision surgery), and 2 patients were unable to return for follow-up, leaving 91 patients available for clinical and radiographic evaluation. At a minimum of 10 years, 3-D wear rates were significantly lower (p < 0.001) in the XLPE group (mean, 0.03 mm/yr) than in the conventional UHMWPE group (mean, 0.27 mm/yr). The prevalence of osteolysis was also significantly lower in the XLPE group (38% versus 8%, p < 0.005), as was the revision rate (14.6% versus 1.9%, p = 0.012), with 10 of the 12 revisions being in the Enduron group. There was no significant difference between the clinical scores of the 2 groups. CONCLUSIONS: XLPE liners have significantly reduced wear and are associated with a greater implant survival rate at 10 years compared with conventional UHMWPE liners. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.