文献速递关节外科

因高位胫骨截骨术失败与单髁膝关节置换术失败行翻修全膝关节置换术在两年随访中患者报告结局相似

Revision total knee arthroplasty for failed high tibial osteotomy and unicompartmental knee arthroplasty have similar patient-reported outcome measures in a two-year follow-up study.
PubMed 文献 · Bone Joint J · 2017-01-01

本研究回顾性分析2001至2014年机构关节登记数据,比较217例高位胫骨截骨术(HTO)翻修全膝关节置换术(TKA)与75例单髁膝关节置换术(UKA)翻修TKA的患者,至少随访两年。两组患者报告结局(PROMs)和满意度相似,但HTO组需再手术的并发症更多,UKA组使用翻修假体更多且手术时间更长。

要点

  • HTO翻修TKA与UKA翻修TKA在两年随访时PROMs和满意度相似。
  • HTO组需再手术的并发症显著多于UKA组。
  • UKA组使用翻修假体更多,导致手术时间更长。

核心结论

  • HTO翻修与UKA翻修TKA获得相似的术后PROMs和满意度。
  • UKA翻修更常需要翻修组件且手术时间增加,但需再手术的并发症少于HTO翻修。

研究设计与样本

  • 回顾性审查机构关节登记数据,纳入2001年至2014年病例,共292例患者,其中217例HTO翻修TKA、75例UKA翻修TKA,至少随访两年。

主要发现

  • 两组在翻修术前人口学特征(年龄、体重指数、Charlson合并症指数)和PROMs(SF-36、牛津膝关节评分、膝关节学会客观与功能评分)相似。
  • 两年随访时两组PROMs较术前均显著改善,两组PROMs和满意度相似。
  • HTO组需再手术的并发症显著更频繁,UKA组使用翻修假体更多,导致手术时间更长。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Little is known about the relative outcomes of revision of unicompartmental knee arthroplasty (UKA) and high tibial osteotomy (HTO) to total knee arthroplasty (TKA). The aim of this study is to compare the outcomes of revision surgery for the two procedures in terms of complications, re-revision and patient-reported outcome measures (PROMs) at a minimum of two years follow-up. PATIENTS AND METHODS: This study was a retrospective review of data from an institutional arthroplasty registry for cases performed between 2001 and 2014. A total of 292 patients were identified, of which 217 had a revision of HTO to TKA, and 75 had revision of UKA to TKA. While mean follow-up was longer for the HTO group compared with the UKA group, patient demographics (age, body mass index and Charlson co-morbidity index) and PROMs (Short Form-36, Oxford Knee Score, Knee Society Score, both objective and functional) were similar in the two groups prior to revision surgery. Outcomes included the rate of complications and re-operation, PROMS and patient-reported satisfaction at six months and two years post-operatively. We also compared the duration of surgery and the need for revision implants in the two groups. RESULTS: At two-year follow-up, both groups of patients had made significant improvement in terms of PROMs compared with pre-operative scores. PROMs and satisfaction rates were similar in the two groups. Complications requiring re-operation were significantly more frequent in the HTO group whilst more revision implants were used in the UKA group, resulting in a longer operative duration. CONCLUSION: Revision of HTO and UKA achieve similar post-operative PROMs and satisfaction. Revision of UKA more frequently requires revision components with increased operation duration but fewer complications requiring re-operation compared with revision of HTO. Cite this article: Bone Joint J 2017;99-B:1329-34.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Lim JBT, Chong HC, Pang HN, et al. Revision total knee arthroplasty for failed high tibial osteotomy and unicompartmental knee arthroplasty have similar patient-reported outcome measures in a two-year follow-up study. Bone Joint J. 2017. PMID: 28963154. doi:10.1302/0301-620X.99B10.BJJ-2017-0034.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。