文献速递关节外科

柄前倾角的解剖学测量能否被视为功能性前倾角

Can Anatomic Measurements of Stem Anteversion Angle Be Considered as the Functional Anteversion Angle?
PubMed 文献 · J Arthroplasty · 2017-09-21

该回顾性病例对照研究纳入191髋(174例)因骨关节炎行全髋关节置换术(THA)的患者,在术前和术后分别于仰卧位和站立位测量股骨旋转角(FRA),以评估解剖学与功能性前倾角测量之间的差异。结果显示FRA存在较大变异性,尤其在术后站立位;术前两体位下绝对FRA均<15°的有134例(70%),术后仅85髋(45%)仍<15°。作者认为解剖学柄前倾角可能不能代表股骨的功能性前倾。

要点

  • 术前FRA仰卧位平均0.3°±8.3°,站立位-4.5°±8.8°;术后仰卧位-3.8°±9.0°,站立位-14.3°±8.3°。
  • 术前两体位下绝对FRA均<15°者134例(70%),术后仅85髋(45%)仍<15°。
  • 作者认为解剖学柄前倾角可能不能代表股骨的功能性前倾。

核心结论

  • FRA存在较大变异性,尤其在术后时期;作者认为解剖学柄前倾角可能不能代表股骨的功能性前倾。

研究设计与样本

  • 回顾性病例对照研究,分析191髋(174例)因骨关节炎行THA的患者。
  • 术前和术后分别于仰卧位和站立位测量FRA,采用CT分割与骨盆及股骨标志点定位,并结合基于强度的2D-3D配准。
  • FRA定义为后髁线与双侧髂前上棘连线之间的角度,外旋为正值。

主要发现

  • 术前FRA仰卧位平均0.3°±8.3°,站立位-4.5°±8.8°;术后FRA仰卧位-3.8°±9.0°,站立位-14.3°±8.3°。
  • 术前两体位下绝对FRA均<15°者134例(70%),术后仅85髋(45%)仍<15°。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Stem anteversion angle is important in the combined anteversion theory to avoid implant impingement after total hip arthroplasty (THA). However, anatomic measurements of stem anteversion angle may not represent functional anteversion of the femur if the femur undergoes axial rotation. Herein, the femoral rotational angle (FRA) was measured in supine and standing positions before and after THA to evaluate the difference between anatomic and functional measurements. METHODS: A total of 191 hips (174 patients) treated with THA for osteoarthritis were analyzed in this retrospective, case-controlled study. The FRA was measured as the angle between the posterior condylar line and the line through the bilateral anterior superior iliac spines (positive for external rotation) and was measured preoperatively and postoperatively in supine and standing positions with computed tomography segmentation and landmark localization of the pelvis and the femur followed by intensity-based 2D-3D registration. The number of cases in which the absolute FRA remained <15° in both positions was also calculated. RESULTS: The average ± standard deviation preoperative FRA was 0.3° ± 8.3° in the supine position and -4.5° ± 8.8° during standing; the postoperative FRA was -3.8° ± 9.0° in supine and -14.3° ± 8.3° during standing. There were 134 cases (70%) in which the preoperative absolute FRA remained <15° in both positions while only 85 hips (45%) remained <15°, postoperatively. CONCLUSION: Substantial variability was seen in the FRA, especially during the postoperative period. These results suggest that the anatomic stem anteversion angle may not represent the functional anteversion of the femur.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Uemura K, Takao M, Otake Y, et al. Can Anatomic Measurements of Stem Anteversion Angle Be Considered as the Functional Anteversion Angle? J Arthroplasty. 2017. PMID: 28993085. doi:10.1016/j.arth.2017.09.027