文献速递关节外科

定制三翼髋臼组件行翻修全髋关节置换术的中期生存率

Midterm Survivorship After Revision Total Hip Arthroplasty With a Custom Triflange Acetabular Component.
PubMed 文献 · J Arthroplasty · 2017-09-21

该研究查询2家高手术量翻修中心的前瞻性登记系统,纳入2000至2011年间使用定制三翼髋臼组件行翻修全髋关节置换术、且随访至少5年的73例患者,平均随访7.5年。结果显示20.5%的组件因无菌性松动外的原因(不稳定8%、感染11%)被翻修,16%因非组件失败原因再手术,中期随访时仅1例影像学松动。作者认为定制三翼重建是严重髋臼缺损的可行选择,但并发症常见。

要点

  • 73例中15例(20.5%)定制三翼组件在随访期内被翻修,其中不稳定6例(8%)、感染8例(11%)。
  • 73例中12例(16%)因非三翼组件失败的原因再手术。
  • 中期随访时髋关节残疾与骨关节炎结局评分关节置换版中位数为85(四分位距73-100),仅1例影像学松动。

核心结论

  • 定制三翼重建是严重髋臼缺损的可行选择,但并发症常见,且组件失败后的处理仍面临重大挑战。

研究设计与样本

  • 查询2家高手术量翻修中心的前瞻性登记系统,纳入2000至2011年间使用定制三翼组件行翻修全髋关节置换术、随访至少5年的73例患者,平均随访7.5年(范围5-12年)。

主要发现

  • 73例中15例(20.5%)定制三翼组件在随访期内被翻修,其中不稳定6例(8%)、感染8例(11%)。
  • 73例中12例(16%)因非三翼组件失败的原因再手术。
  • 中期随访时髋关节残疾与骨关节炎结局评分关节置换版中位数为85(四分位距73-100)。
  • 73例中仅1例在中期随访时被判定为影像学松动。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Custom triflange acetabular components are being increasingly used for the reconstruction of Paprosky type IIIB acetabular defects. However, midterm survivorship data are lacking. METHODS: We queried the prospective registries at 2 high-volume revision centers for patients who had undergone revision total hip arthroplasty using a custom triflange component between 2000 and 2011. We identified 73 patients with minimum 5-year follow-up. These patients' records were reviewed to determine incidence of revision or reoperation, clinical performance, and radiographic stability. The mean follow-up was 7.5 years (range 5-12 years). RESULTS: Fifteen of 73 triflange components (20.5%) were indicated for revision during the follow-up period, including 6 for instability (8%) and 8 for infection (11%). Twelve of 73 patients (16%) underwent reoperation for reasons other than failure of the triflange component. The median hip disability and osteoarthritis outcome score for joint replacement score at midterm follow-up was 85 (interquartile range 73-100). Only 1 of 73 implants was determined to be radiographically loose at midterm follow-up. CONCLUSION: Custom triflange reconstruction for severe acetabular deficiency is a viable option; however, complications are common and significant challenges remain for those that fail.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Gladnick BP, Fehring KA, Odum SM, et al. Midterm Survivorship After Revision Total Hip Arthroplasty With a Custom Triflange Acetabular Component. J Arthroplasty. 2017. PMID: 29033157. doi:10.1016/j.arth.2017.09.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。