活动平台全膝关节置换术中的脱位/旋转脱位:26例报告
基于8373例连续初次活动平台全膝关节置换术,报告26例旋转脱位(0.31%)。2001年前后两个队列对比显示,不松解韧带并使用更高形合度平台后旋转脱位发生率从0.58%降至0.2%(P<.01),旋转脱位与膝外翻相关,多数发生在术后6个月内,通常可闭合复位。
要点
- 旋转脱位发生率为0.31%(26/8373),与膝外翻相关(P<.01),73%发生在术后6个月内。
- 2001年后不松解韧带并使用更高形合度活动平台,旋转脱位发生率从0.58%(14/2379)降至0.2%(12/5994),P<.01。
- 旋转脱位通常可闭合复位且复发不常见,不应作为反对活动平台全膝关节置换术的理由。
核心结论
- 旋转脱位的病因是屈曲间隙不稳定,通常可闭合复位且复发不常见。
- 关注活动平台全膝关节置换术中的软组织平衡可较固定平台降低因不稳定而翻修的发生率,因此旋转脱位风险不应作为反对活动平台全膝关节置换术的理由。
研究设计与样本
- 1993年10月至2016年2月间连续施行8373例初次活动平台全膝关节置换术,不论术前畸形。
- 以2001年为界形成两个对比队列:第一队列截至2001年5月,共2379例;第二队列为2001年5月后手术者,共5994例。
主要发现
- 8373例中发生26例旋转脱位(0.31%)。
- 第一队列2379例中发生14例旋转脱位(0.58%);第二队列5994例中发生12例旋转脱位(0.2%),显著低于第一队列(P<.01)。
- 旋转脱位与膝外翻相关(P<.01),73%发生在术后前6个月内。
- 第一队列有1例关节融合,第二队列有1例双组件翻修。
关键数值与推荐
- 2001年前通过松解侧副韧带实现软组织平衡,所有旋转脱位均行切开复位。
- 2001年后不松解韧带实现软组织平衡并使用更高形合度活动平台,所有旋转脱位均行闭合复位。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Excellent medium-term to long-term results for function and survivorship have been shown with mobile-bearing (MB) total knee arthroplasty (TKA). One of the key arguments against its use is the risk of "spinout" or dislocation of the MB. The aim of this study is to discuss the etiology, prevention, incidence, management, and outcome of spinout. METHODS: Between October 1993 and February 2016, 8373 consecutive primary MB TKAs were performed irrespective of preoperative deformity. Before 2001, soft-tissue knee balancing was achieved by release of collateral ligaments and all spinouts were treated by open reduction. Thereafter, soft-tissue balancing was achieved without ligament release and with the use of a higher conformity MB and all spinouts were reduced closed, giving 2 comparative cohorts. RESULTS: Twenty-six spinouts occurred in 8373 (0.31%) patients. In the first cohort up until May 2001, there were 14 spinouts of 2379 (0.58%) cases. There were 12 in cohort 2, in those patients having surgery after May 2001, thus giving an incidence of 12 of 5994 (0.2%), which was significantly lower than in cohort 1 (P < .01). Spinout was associated with the valgus knee (P < .01) and most (73%) occurred within the first 6 months. There was 1 arthrodesis in cohort 1 and 1 both-component revision in cohort 2. CONCLUSION: The etiology of spinout is flexion gap instability. It can normally be reduced closed with recurrence being uncommon. Focus on soft-tissue balance necessary with an MB TKA can reduce the incidence of revision for instability as compared to a fixed-bearing TKA. Therefore, the risk of spinout should not be used as an argument against the MB TKA.
引用
- Diamond OJ, Doran E, Beverland DE, et al. Spinout/Dislocation in Mobile-Bearing Total Knee Arthroplasty: A Report of 26 Cases. J Arthroplasty. 2017. PMID: 29056307. doi:10.1016/j.arth.2017.09.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。