文献速递脊柱外科创伤骨科

颈椎与上胸椎CT导航椎弓根螺钉置入在有无前路手术及前路钢板固定时的准确性

Accuracy of CT-navigated pedicle screw positioning in the cervical and upper thoracic region with and without prior anterior surgery and ventral plating.
PubMed 文献 · Bone Joint J · 2017-01-01

回顾性分析107例连续手术患者的592枚椎弓根螺钉,按Gertzbein和Robbins分级在术后CT评估置入准确性。总体准确率为88.5%,颈椎87.7%、胸椎89%;既往前路手术组(COMB)准确率82.9%显著低于单纯后路组(POST)91.6%(p=0.036)。无神经并发症,记录到2例椎动脉损伤,3例因螺钉位置不良行翻修手术。

要点

  • CT导航下颈椎和上胸椎椎弓根螺钉置入总体准确率为88.5%(524/592枚)。
  • COMB组准确率82.9%显著低于POST组91.6%(p=0.036),既往前路手术者置钉风险约为单纯后路手术的2.4倍。
  • 无神经并发症,记录到2例椎动脉损伤,3例患者因螺钉位置不良接受翻修手术。

核心结论

  • CT导航下椎弓根螺钉可安全置入,但对既往接受过前路手术的患者需更加谨慎。

研究设计与样本

  • 回顾性评估107例连续手术患者共592枚椎弓根螺钉的置入准确性和安全性,其中COMB组210枚、POST组382枚。
  • 根据术后CT扫描采用Gertzbein和Robbins分类判定置入准确性,并采用logistic回归混合模型分析低准确性的风险。

主要发现

  • 总体524枚螺钉(88.5%)置入准确,颈椎192枚(87.7%)、胸椎332枚(89%)置入准确。
  • COMB组准确率82.9% vs POST组91.6%(p=0.036),COMB组显著低于POST组。
  • 无神经并发症,记录到2例椎动脉损伤,3例患者因螺钉位置不良接受翻修手术。
  • 初次前路手术后螺钉位置不良的风险估计为单纯后路手术的2.4倍,但总体并发症率和翻修率低。

关键数值与推荐

  • 准确性判定采用Gertzbein和Robbins分类,基于术后CT扫描评估。
  • COMB组准确率82.9% vs POST组91.6%(p=0.036)。
  • COMB组螺钉位置不良风险为POST组的2.4倍。

临床怎么用

  • CT导航下椎弓根螺钉可安全置入,但既往接受前路手术的患者需更加谨慎。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: We aimed to retrospectively assess the accuracy and safety of CT navigated pedicle screws and to compare accuracy in the cervical and thoracic spine (C2-T8) with (COMB) and without (POST) prior anterior surgery (anterior cervical discectomy or corpectomy and fusion with ventral plating: ACDF/ACCF). PATIENTS AND METHODS: A total of 592 pedicle screws, which were used in 107 consecutively operated patients (210 COMB, 382 POST), were analysed. The accuracy of positioning was determined according to the classification of Gertzbein and Robbins on post-operative CT scans. RESULTS: High accuracy was achieved in 524 screws (88.5%), 192 (87.7%) in the cervical spine and 332 (89%) in the thoracic spine, respectively. The results in the two surgical groups were compared and a logistic regression mixed model was performed to analyse the risk of low accuracy. Significantly lower accuracy was found in the COMB group with 82.9% versus 91.6% in the POST group (p = 0.036). There were no neurological complications, but two vertebral artery lesions were recorded. Three patients underwent revision surgery for malpositioning of a screw. Although the risk of malpositioning of a screw after primary anterior surgery was estimated to be 2.4-times higher than with posterior surgery alone, the overall rates of complication and revision were low. CONCLUSION: We therefore conclude that CT navigated pedicle screws can be positioned safely although greater caution must be taken in patients who have previously undergone anterior surgery. Cite this article: Bone Joint J 2017;99-B:1373-80.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Rienmüller A, Buchmann N, Kirschke JS, et al. Accuracy of CT-navigated pedicle screw positioning in the cervical and upper thoracic region with and without prior anterior surgery and ventral plating. Bone Joint J. 2017. PMID: 28963160. doi:10.1302/0301-620X.99B10.BJJ-2016-1283.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。