Kotz模块化股骨胫骨重建系统中的组件骨折:一种被低估的并发症
本研究回顾了221例接受Kotz模块化股骨胫骨重建系统(KMFTR)重建的患者,其中27例(12%)发生假体骨折,平均骨折时间为术后7年。与未骨折患者相比,骨折患者髓内柄直径显著更小(12 vs 14 mm,P=0.001),髓外组件长度显著更长(18 vs 15 cm,P=0.04)。骨折患者与未骨折患者的术前和术后多伦多肢体挽救评分(P=0.98)、肌肉骨骼肿瘤协会87评分(P=0.78)和肌肉骨骼肿瘤协会93评分(P=1.0)均无差异。
要点
- KMFTR重建后假体组件骨折率为12%(27/221),平均发生于术后7年。
- 骨折最常累及股骨远端(n=21)和柄上的螺钉孔(n=12)。
- 柄直径较小(12 vs 14 mm,P=0.001)和髓外组件较长(18 vs 15 cm,P=0.04)与假体骨折显著相关。
核心结论
- 本研究表明骨折是与KMFTR柄相关的被低估的并发症,假体组件骨折率为12%。
- 柄直径较小和切除长度较长的患者更可能发生柄骨折。
- 后续翻修提供了持久的重建手段,患者功能无显著丧失。
研究设计与样本
- 回顾性综述了221例接受KMFTR重建的患者(95例女性,126例男性)。
主要发现
- 27例患者(12%)发生假体骨折,平均骨折时间为术后7年。
- 骨折组件最常累及股骨远端(n=21)和柄上的螺钉孔(n=12)。
- 在柄骨折患者(n=21)中,平均髓内柄直径为12 mm,平均髓外组件长度为18 cm。
- 与未骨折患者相比,骨折患者柄直径显著更小(12 vs 14 mm,P=0.001),髓外组件长度显著更长(18 vs 15 cm,P=0.04)。
- 骨折患者与未骨折患者的术前和术后多伦多肢体挽救评分(P=0.98)、肌肉骨骼肿瘤协会87评分(P=0.78)和肌肉骨骼肿瘤协会93评分(P=1.0)均无差异。
临床怎么用
- 作者指出,后续翻修提供了持久的重建手段,患者功能无显著丧失。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Primary bone tumors of the femur are commonly reconstructed using an endoprosthesis. Different modes of implant failure have been described, including structural failure; although uncommon, this may be an under-reported complication. The purpose of this study is to examine the rates and risk factors for implant fracture of the Kotz Modular Femoral Tibial Reconstruction system (KMFTR). METHODS: Two hundred twenty-one patients (95 women and 126 men) who underwent a KMFTR reconstruction were reviewed. Twenty-seven patients (12%) sustained a prosthetic fracture. The mean time to fracture was 7 years postoperatively. The fractured component most commonly involved the distal femur (n = 21) and a screw hole in the stem (n = 12). In patients with stem fractures (n = 21), the mean intramedullary stem diameter was 12 mm and the mean extramedullary component length was 18 cm. RESULTS: Compared to patients who did not fracture, those with a prosthetic fracture had a significantly smaller stem diameter (12 vs 14 mm, P = .001) and a significantly longer extramedullary component length (18 vs 15 cm, P = .04). There was no difference between the preoperative and postoperative Toronto Extremity Salvage Scores (P = .98), Musculoskeletal Tumor Society 87 (P = .78), or Musculoskeletal Tumor Society 93 (P = 1.0) ratings for patients with or without a prosthetic fracture. CONCLUSION: This study shows that fracture is an under-reported complication associated with the KMFTR stem. We identified an endoprosthetic component fracture rate of 12%. Patients with smaller stem diameter and longer resection lengths were more likely to sustain a stem fracture. Subsequent revision provides a durable means of reconstruction, with no significant loss of patient function.
引用
- Hauer TM, Houdek MT, Bhumbra R, et al. Component Fracture in the Kotz Modular Femoral Tibial Reconstruction System: An Under-Reported Complication. J Arthroplasty. 2017. PMID: 29033156. doi:10.1016/j.arth.2017.09.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。