缝合带增强的踝外侧韧带翻修解剖重建术用于Broström手术失败患者
这项前瞻性研究评估了缝合带增强的翻修解剖踝韧带重建术治疗改良Broström手术失败后的踝关节持续不稳。30例患者中24例随访超过两年,末次随访时FAOS和FAAM评分显著改善,距骨倾斜角和距骨前移显著改善,仅1例翻修失败。作者认为该技术在中短期随访中提供可靠稳定性和满意临床结局。
要点
- 缝合带增强的翻修改良Broström手术用于Broström术后复发不稳,末次随访FAOS和FAAM评分显著改善。
- 末次随访距骨倾斜角和距骨前移显著改善,应力位X线片侧侧对比无显著差异。
- 24例随访患者中1例翻修失败,接受同种异体肌腱再次翻修。
核心结论
- 缝合带增强的翻修改良Broström手术是治疗Broström手术失败后踝关节复发不稳的有效方法。
- 该技术在中短期随访中提供可靠稳定性和满意临床结局。
研究设计与样本
- 前瞻性研究,共30例Broström术后持续踝关节不稳患者接受缝合带增强的翻修手术,其中24例随访超过两年纳入研究。
- 24例中男13例、女11例,平均年龄31.8岁(23至44岁),平均随访38.5个月(24至56个月)。
- 临床结局采用足踝结局评分(FAOS)和足踝能力测量(FAAM)评估,踝关节稳定性采用应力位X线片评估。
主要发现
- 末次随访平均FAOS评分显著改善至87.5分(73至94分)(p < 0.001)。
- 末次随访平均FAAM评分显著改善至85.1分(70至95分)(p < 0.001)。
- 末次随访平均距骨倾斜角显著改善至2.8°(0°至6°)(p < 0.001)。
- 末次随访平均距骨前移显著改善至4.1 mm(2至7 mm)(p < 0.001)。
- 末次随访应力位X线片侧侧对比无显著差异;1例患者翻修失败,接受同种异体肌腱再次翻修。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aim of this prospective study was to evaluate the intermediate-term outcomes after revision anatomical ankle ligament reconstruction augmented with suture tape for a failed modified Broström procedure. PATIENTS AND METHODS: A total of 30 patients with persistent instability of the ankle after a Broström procedure underwent revision augmented with suture tape. Of these, 24 patients who were followed up for more than two years were included in the study. There were 13 men and 11 women. Their mean age was 31.8 years (23 to 44). The mean follow-up was 38.5 months (24 to 56) The clinical outcome was assessed using the Foot and Ankle Outcome Score (FAOS) and the Foot and Ankle Ability Measure (FAAM) score. The stability of the ankle was assessed using stress radiographs. RESULTS: The mean FAOS and FAAM scores improved significantly to 87.5 (73 to 94) and 85.1 (70 to 95) points at final follow-up, respectively (p < 0.001). The mean angle of talar tilt and anterior talar translation improved significantly to 2.8° (0° to 6°) and 4.1 mm (2 to 7) at final follow-up, respectively (p < 0.001). Side to side comparison in stress radiographs at final follow-up showed no significant difference. The revision failed in one patient who underwent a further revision using allograft tendon. CONCLUSION: The revision modified Broström procedure augmented with suture tape is an effective form of treatment for recurrent instability of the ankle following a failed Broström procedure. This technique provides reliable stability and satisfactory clinical outcomes at intermediate-term follow-up. Cite this article: Bone Joint J 2017;99-B:1183-9.
引用
- Cho BK, Kim YM, Choi SM, et al. Revision anatomical reconstruction of the lateral ligaments of the ankle augmented with suture tape for patients with a failed Broström procedure. Bone Joint J. 2017. PMID: 28860398. doi:10.1302/0301-620X.99B9.BJJ-2017-0144.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。