小梁金属髋臼组件降低初次全髋关节置换术后翻修风险:基于英格兰与威尔士国家关节登记系统的倾向评分匹配研究

Trabecular Metal Acetabular Components Reduce the Risk of Revision Following Primary Total Hip Arthroplasty: A Propensity Score Matched Study From the National Joint Registry for England and Wales.
PubMed 文献 · J Arthroplasty · 2017-09-05

基于英格兰与威尔士国家关节登记系统的回顾性观察研究,纳入18,200例初次全髋关节置换(9,100例小梁金属与非小梁金属涂层髋臼组件经倾向评分匹配),比较翻修率。小梁金属组5年全因翻修率(1.0% vs 1.8%,SHR 0.57,95%CI 0.43-0.76,P<.001)、无菌性髋臼松动翻修率(0.1% vs 0.2%,SHR 0.35,95%CI 0.14-0.90,P=.029)和感染翻修率(0.5% vs 0.9%,SHR 0.51,95%CI 0.34-0.76,P=.001)均低于非小梁金属组。结论认为小梁金属涂层髋臼植入物可降低无菌性和感染性翻修风险,绝对差异虽小但在更复杂病例中可能具有临床意义。

要点

  • 小梁金属组5年全因翻修率为1.0%,非小梁金属组为1.8%(SHR 0.57,95%CI 0.43-0.76,P<.001)。
  • 小梁金属组5年无菌性髋臼松动翻修率为0.1%,非小梁金属组为0.2%(SHR 0.35,95%CI 0.14-0.90,P=.029)。
  • 小梁金属组5年感染翻修率为0.5%,非小梁金属组为0.9%(SHR 0.51,95%CI 0.34-0.76,P=.001)。

核心结论

  • 初次全髋关节置换术后,小梁金属涂层髋臼植入物与非小梁金属植入物相比,无菌性和感染性翻修风险均降低。
  • 翻修风险的绝对差异虽小,但若将小梁金属设计植入更复杂病例,可能具有临床意义。

研究设计与样本

  • 回顾性观察研究,使用英格兰与威尔士国家关节登记系统数据,纳入使用同一非骨水泥髋臼组件(小梁金属或非小梁金属涂层)的初次全髋关节置换。
  • 小梁金属与非小梁金属植入物通过倾向评分匹配多个潜在混杂因素,匹配后共18,200例初次全髋关节置换(小梁金属9,100例,非小梁金属9,100例)。
  • 采用竞争风险回归分析比较匹配组间结局(全因髋臼指征翻修、无菌性髋臼松动翻修和感染翻修)。

主要发现

  • 18,200例初次全髋关节置换中,髋臼翻修、无菌性髋臼松动翻修和感染性翻修的总患病率分别为1.2%、0.13%和0.59%。
  • 5年全因翻修率小梁金属组为1.0%,非小梁金属组为1.8%(SHR 0.57,95%CI 0.43-0.76,P<.001)。
  • 5年无菌性髋臼松动翻修率小梁金属组为0.1%,非小梁金属组为0.2%(SHR 0.35,95%CI 0.14-0.90,P=.029)。
  • 5年感染翻修率小梁金属组为0.5%,非小梁金属组为0.9%(SHR 0.51,95%CI 0.34-0.76,P=.001)。

关键数值与推荐

  • 5年全因翻修率:小梁金属组1.0% vs 非小梁金属组1.8%(SHR 0.57,95%CI 0.43-0.76,P<.001)。
  • 5年无菌性髋臼松动翻修率:小梁金属组0.1% vs 非小梁金属组0.2%(SHR 0.35,95%CI 0.14-0.90,P=.029)。
  • 5年感染翻修率:小梁金属组0.5% vs 非小梁金属组0.9%(SHR 0.51,95%CI 0.34-0.76,P=.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Trabecular metal (TM)-coated acetabular components are increasingly used in both primary and revision total hip arthroplasty (THA). However, previous studies assessing TM acetabular components have been small single-center cohorts with most lacking a control group. We compared revision rates following primary THA between TM and non-TM-coated acetabular components. METHODS: A retrospective observational study was performed using National Joint Registry data, which included primary THAs with the same cementless acetabular component (either TM or non-TM coated). TM and non-TM implants were matched for multiple potential confounding factors using propensity scores. Outcomes following primary THA (revision for all-cause acetabular indications, aseptic acetabular loosening, and infection) were compared between matched groups using competing risk regression analysis. RESULTS: In 18,200 primary THAs (9100 TM and 9100 non-TM), the overall prevalence of acetabular revision, revision for aseptic acetabular loosening, and septic revision was 1.2%, 0.13%, and 0.59% respectively. Five-year revision rates for all-causes (1.0% vs 1.8%, sub-hazard ratio [SHR] 0.57, 95% confidence interval [CI] 0.43-0.76, P < .001), aseptic acetabular loosening (0.1% vs 0.2%, SHR 0.35, 95% CI 0.14-0.90, P = .029), and infection (0.5% vs 0.9%, SHR 0.51, 95% CI 0.34-0.76, P = .001) were all lower in TM compared with non-TM implants. CONCLUSION: Following primary THA, TM-coated acetabular implants had a reduced risk of both aseptic and septic revision compared with non-TM implants. Although absolute differences in revision risk were small, they may be clinically significant if TM designs were implanted in more complex cases.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Matharu GS, Judge A, Murray DW, et al. Trabecular Metal Acetabular Components Reduce the Risk of Revision Following Primary Total Hip Arthroplasty: A Propensity Score Matched Study From the National Joint Registry for England and Wales. J Arthroplasty. 2017. PMID: 28947370. doi:10.1016/j.arth.2017.08.036