全髋关节置换术后静脉血流动力学:便携式与固定式气动压缩装置比较及体位影响

Venous Hemodynamics After Total Hip Arthroplasty: A Comparison Between Portable vs Stationary Pneumatic Compression Devices and the Effect of Body Position.
PubMed 文献 · J Arthroplasty · 2017-08-24

交叉研究比较便携式与固定式气动压缩装置在仰卧位和站立位对静脉血流动力学的影响,纳入10名对照和10名全髋关节置换患者。两种体位下固定式装置引起的峰值静脉流速变化均大于便携式装置(P < .001);站立位时固定式装置的流速变化更大,便携式装置站立与仰卧无差异。

要点

  • 两种体位下固定式气动压缩装置引起的峰值静脉流速变化均大于便携式装置(P < .001)。
  • 站立位时固定式装置的血流动力学增益大于仰卧位,便携式装置两种体位无差异。
  • 全髋关节置换组站立位时两种装置合计的流速变化大于对照组(P < .001)。

核心结论

  • 固定式气动压缩装置在仰卧位和站立位增加峰值静脉流速的能力均大于便携式装置。
  • 固定式装置在站立位产生的峰值静脉流速及流速变化值更大。
  • 作者指出,在确定预防静脉血栓栓塞所需的峰值静脉流速之前,尚不能认为某一装置更有效。

研究设计与样本

  • 交叉研究,比较便携式气动压缩装置(ActiveCare+S.F.T.)与固定式气动压缩装置(VenaFlow)在仰卧位和站立位对血流动力学的影响。
  • 评估基线峰值静脉流速、使用每种装置时的峰值静脉流速及流速变化值,并进行多因素分析考察队列、装置和体位间的差异。

主要发现

  • 两种体位下,固定式装置引起的峰值静脉流速变化均大于便携式装置(P < .001)。
  • 全髋关节置换组站立位时两种装置合计的流速变化值大于对照组(P < .001)。
  • 两组合并分析时,仅在使用固定式装置时站立位的流速变化值大于仰卧位(P < .001)。
  • 使用便携式装置时,站立位与仰卧位之间无差异。

局限性

  • 作者指出,在确定预防静脉血栓栓塞所需的峰值静脉流速之前,尚不能认为某一装置更有效。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Improvements in device design have allowed for portable pneumatic compression devices (PPCDs). However, portability results in smaller pumps that move less blood. Additionally, although patients often stand when wearing PPCDs, few studies have evaluated the hemodynamic effects of PCDs while standing. METHODS: A crossover study was performed to compare a PPCD (ActiveCare+S.F.T.; Medical Compression Systems, Or Akiva, Israel) to a stationary pneumatic compression device (SPCD) (VenaFlow; DJO Global, Carlsbad, CA) on hemodynamics in supine and standing positions among 2 cohorts composed of 10 controls and 10 total hip arthroplasty patients. Differences in baseline peak venous velocity (PVV), PVV with each PCD, and delta PVV with each PCD were assessed. A multivariate analysis was performed to examine differences between cohorts, devices, and position. RESULTS: In both positions, the SPCD demonstrated a larger change in PVV when compared to the PPCD (P < .001). The total hip arthroplasty group had a greater delta PVV while standing when considering both PCDs together (P < .001). When considering both cohorts, delta PVV was greater while standing, only when the SPCD was used (P < .001). There was no difference between standing and supine positions when the PPCD was used. CONCLUSION: The SPCD demonstrated a greater capacity to increase PPV in the supine and standing positions. The SPCD generated greater values of PVV and delta PVV in the standing position. Although these results demonstrate a difference between devices, it is important to establish the PVV necessary to prevent VTE before one is considered more effective.

来源:J Arthroplasty,查看原文。版权归原作者所有。