iAssist手持导航系统与传统器械在全膝关节置换术机械轴恢复中的比较
iAssist组胫骨或股骨假体对线误差大于3°的患者比例为4.0%,传统组为36.0%(P < .05);iAssist组股骨和胫骨机械轴变异均显著小于传统组(P < .005),而止血带时间和失血量两组无显著差异。
要点
- iAssist导航组术后假体对线误差大于3°者为4.0%,传统器械组为36.0%(P < .05)。
- iAssist组股骨机械轴变异1.65° ± 0.17° vs 传统组2.23° ± 0.33°(P < .005)。
- iAssist组胫骨机械轴变异1.28° ± 0.13° vs 传统组1.71° ± 0.24°(P < .005)。
核心结论
- 在全膝关节置换术中使用iAssist系统较传统器械可改善术后机械轴并降低对线变异,且不显著增加手术时间。
研究设计与样本
- 前瞻性随机研究,将行全膝关节置换术的患者随机分为iAssist导航组(n = 25)和传统器械组(n = 25)。
- 术前和术后机械轴通过下肢全长X线片测量以评估对线,并评估止血带时间和失血量等手术参数。
主要发现
- 术后iAssist导航组4.0%的患者胫骨或股骨假体对线误差大于3°,传统器械组为36.0%(P < .05)。
- iAssist组股骨机械轴变异为1.65° ± 0.17°,传统组为2.23° ± 0.33°(P < .005)。
- iAssist组胫骨机械轴变异为1.28° ± 0.13°,传统组为1.71° ± 0.24°(P < .005)。
- 两组止血带时间(P = .86)和失血量(P = .39)无显著差异。
- 两组患者人口学特征和术前机械轴对线相似。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Recent advances in total knee arthroplasty (TKA) include an intelligent instrument system designed to provide intraoperative guidance to reduce mechanical alignment errors. Internal position-sensing technology is integrated into microelectronic pods that attach to cutting blocks. The purpose of this prospective, randomized study was to determine whether this iAssist system enables the surgeon to make more accurate bone resections and better restore the mechanical axis compared to conventional instruments in TKA. METHODS: We randomized patients undergoing TKA into 2 groups. Group I (n = 25) underwent TKA assisted by the iAssist guidance system, group II (n = 25) underwent TKA using conventional instruments. Preoperative and postoperative mechanical axes were measured from full-length lower extremity radiographs to evaluate alignment. Additional surgical parameters were also assessed, including tourniquet time and blood loss. RESULTS: Patient demographics and preoperative mechanical axis alignments were similar between the groups. Postoperatively, 4.0% of patients had greater than 3° of tibial or femoral component mal-alignment in the guidance-assisted cohort, compared with 36.0% in the conventional group (P < .05). Additionally, group I showed significant improvement in variance seen in both the femoral mechanical axis (1.65° ± 0.17° vs 2.23° ± 0.33°, P < .005) and tibial mechanical axis (1.28° ± 0.13° vs 1.71° ± 0.24°, P < .005) compared to group II. There were no significant differences in tourniquet time (P = .86) or blood loss (P = .39) between groups. CONCLUSION: Use of the iAssist system in TKA results in an improved postoperative mechanical axis and decreased alignment variability compared to conventional instruments, without significantly increasing operative time.
引用
- Kinney MC, Cidambi KR, Severns DL, et al. Comparison of the iAssist Handheld Guidance System to Conventional Instruments for Mechanical Axis Restoration in Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28867520. doi:10.1016/j.arth.2017.06.004