模块化股骨柄在金属对金属全髋关节置换术中影像学与功能结果较差
研究分析539例单侧金属对金属全髋关节置换(ASR XL)患者,比较Summit(48%)、Corail(35%)或S-ROM(17%)股骨柄在平均6.4年随访时骨溶解、透亮线、血金属离子水平及功能结局的差异。结果显示S-ROM股骨柄患者骨溶解风险为Summit的3.8倍(P=.003),透亮线风险为7.6倍(P<.001),且5项患者报告结局中4项(Harris髋关节评分、视觉模拟疼痛评分、加州大学洛杉矶分校活动评分、EQ-5D指数)显著较差,差异范围5%至10%具临床意义。
要点
- S-ROM股骨柄患者骨溶解风险为Summit的3.8倍(P=.003),透亮线风险为7.6倍(P<.001)。
- S-ROM股骨柄在Harris髋关节评分、视觉模拟疼痛评分、加州大学洛杉矶分校活动评分及EQ-5D指数4项患者报告结局中均显著差于Summit。
- 作者认为需对大口径头金属对金属全髋关节置换患者进行取回研究并密切随访以理解不同股骨柄间结局差异的机制。
核心结论
- S-ROM股骨柄患者的影像学与功能结果均差于Summit股骨柄患者。
- 作者认为需对大口径头金属对金属全髋关节置换进行取回研究并密切随访这些带股骨柄的患者,以理解不同股骨柄间结局差异的机制。
研究设计与样本
- 研究分析539例单侧金属对金属全髋关节置换(ASR XL),分别配对Summit(48%)、Corail(35%)或S-ROM(17%)股骨柄,平均随访6.4年。
- 患者中54%为男性,平均年龄60岁;研究评估了X线片、患者报告结局指标及离子水平。
主要发现
- S-ROM股骨柄患者发生骨溶解的可能性为Summit股骨柄患者的3.8倍(P=.003)。
- S-ROM股骨柄患者发生透亮线的可能性为Summit股骨柄患者的7.6倍(P<.001)。
- S-ROM股骨柄患者在5项患者报告结局指标中的4项(Harris髋关节评分、视觉模拟疼痛评分、加州大学洛杉矶分校活动评分及EQ-5D指数)评分差于Summit股骨柄患者,差异均有统计学意义,范围5%至10%,具临床意义。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Data on the association between stem type and metal-on-metal (MoM) total hip arthroplasty (THA) performance are limited. The aim of this study is to investigate the effect of stem type on the prevalence of osteolysis and radiolucency, blood metal ion levels, and functional outcomes in patients with Articular Surface Replacement THA (ASR XL), a type of MoM THA. METHODS: We analyzed 539 unilateral MoM THAs coupled with Summit (48%), Corail (35%), or S-ROM (17%) hip stems at a mean follow-up of 6.4 years. Fifty-four percent of the patients were male, and the mean age was 60 years. We studied radiographs, patient-reported outcome measures, and ion levels. RESULTS: Patients with S-ROM hip stems were 3.8 times more likely to have osteolysis (P = .003) and 7.6 times more likely to have radiolucency (P < .001) than those treated with Summit hip stems. In addition, patients treated with S-ROM hip stems scored worse than those with Summit hip stems in 4 of the 5 patient-reported outcome measures: Harris Hip Score, Visual Analog Scale pain, University of California at Los Angeles activity, and EQ-5D index. All these differences were statistically significant and ranged from 5% to 10%, which is clinically significant. CONCLUSION: Patients with S-ROM hip stems had inferior functional and radiographic results compared to patients with Summit hip stems. Retrieval studies on large diameter head MoM THA and close follow-up of these patients with hip stems are needed to understand the mechanism causing the differences in outcomes between these stem types.
引用
- Laaksonen I, Galea VP, Connelly JW, et al. Inferior Radiographic and Functional Outcomes With Modular Stem in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty. 2017. PMID: 28947371. doi:10.1016/j.arth.2017.08.042
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。