全膝关节置换术后灾难性内翻塌陷患者的影像学表现
该研究回顾2004至2017年1106例翻修全膝关节置换术,其中35例因胫骨内翻塌陷翻修,27例初次置换在本院完成。患者平均体重指数38 kg/m²,26/27例术前存在内翻畸形(4.2°内翻),术后均矫正为外翻对线(5.2°外翻,P = .0001)。作者建议对术前内翻畸形、胫骨假体尺寸小且体重指数≥35 kg/m²的行初次全膝关节置换术患者,可考虑增加胫骨延长杆长度。
要点
- 灾难性内翻塌陷是初次全膝关节置换术不常见的失败机制。
- 27例中26例术前存在内翻畸形(4.2°内翻),术后均矫正为外翻对线(5.2°外翻,P = .0001)。
- 作者建议对术前内翻畸形、胫骨假体尺寸小且体重指数≥35 kg/m²者,可考虑增加胫骨延长杆长度。
核心结论
- 胫骨内翻塌陷是初次全膝关节置换术后不常见的失败原因。
- 术前内翻畸形、术后胫骨内侧骨丢失和肥胖是该系列患者的常见表现。
- 作者建议对术前存在内翻畸形、胫骨假体尺寸小且体重指数≥35 kg/m²的行初次全膝关节置换术患者,可考虑增加胫骨延长杆长度。
研究设计与样本
- 利用机构数据库回顾2004至2017年1106例翻修全膝关节置换术,其中35例因胫骨内翻塌陷翻修。
- 35例中27例初次全膝关节置换术在本机构完成,从膝关节正位X线片记录冠状面对线,末次随访记录胫骨内侧骨丢失。
主要发现
- 患者平均体重指数为38 kg/m²。
- 27例中26例术前存在内翻畸形(4.2°内翻),术后即刻均矫正为外翻冠状面对线(5.2°外翻,P = .0001)。
- 27例中24例内翻塌陷后的冠状面对线与术前对线相差在2°以内(5.8°内翻)。
- 27例中25例在内翻塌陷前存在影像学胫骨内侧骨丢失。
临床怎么用
- 作者建议对术前存在内翻畸形、胫骨假体尺寸小且体重指数≥35 kg/m²的行初次全膝关节置换术患者,可考虑增加胫骨延长杆长度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Catastrophic varus collapse is an uncommon mechanism of failure in primary total knee arthroplasty (TKA). Varus collapse has been associated with obesity and smaller implant sizes. However, to our knowledge, preoperative radiographic characterization of this cohort has not been performed. Therefore, the following study evaluated preoperative alignment and how this correlates with the degree of eventual varus collapse identified in this patient population prior to revision. METHODS: Utilizing our institutional database, 1106 revision TKAs were performed from 2004 to 2017. Of these, 35 patients were revised secondary to tibial varus collapse. Twenty-seven patients had their primary TKA performed at our institution. Coronal alignment of the knee was recorded from anteroposterior knee radiographs. Medial tibial bone loss was recorded at final follow-up. RESULTS: The average body mass index was 38 kg/m2. Twenty-six of 27 patients had a preoperative varus deformity (4.2° varus) and all were corrected to a valgus coronal alignment immediately postoperatively (5.2° valgus, P = .0001). Twenty-four of 27 patients' coronal alignment after varus collapse was within 2° of their preoperative alignment (5.8° varus). Twenty-five of 27 patients had radiographic medial tibial bone loss prior to varus collapse. CONCLUSION: Tibial varus collapse in an uncommon cause of failure after primary TKA. Preoperative varus deformity, postoperative medial tibial bone loss, and obesity were common findings in this series of patients. Therefore, increased tibial stem lengths should be considered in patients with a preoperative varus deformity, small tibial implant size, and a body mass index ≥35 kg/m2 undergoing primary TKA.
引用
- Martin JR, Fehring KA, Watts CD, et al. Radiographic Findings in Patients With Catastrophic Varus Collapse After Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28899593. doi:10.1016/j.arth.2017.08.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。