全膝关节置换术中采用骨岛技术保护后交叉韧带
研究将60具防腐尸体标本随机分为实验组和对照组,评估在交叉韧带保留型全膝关节置换术中使用骨凿保留骨岛对后交叉韧带的保护效果。对照组后交叉韧带损伤率为73%(22/30),实验组为23%(7/30),骨凿使用带来50%的绝对风险降低。作者认为在手术经验有限的情况下,骨凿形成骨岛是保护后交叉韧带的更有效方法。
要点
- 对照组后交叉韧带损伤率为73%(22/30),实验组为23%(7/30)。
- 使用骨凿保护骨岛的绝对风险降低为50%。
- 作者认为手术经验有限时,骨凿形成骨岛是保护后交叉韧带的更有效方法。
核心结论
- 在手术经验有限的情况下,使用骨凿形成骨岛在交叉韧带保留型全膝关节置换术中保护后交叉韧带的效果优于标准技术。
- 标准技术联合Y形后交叉韧带拉钩对后交叉韧带的保护作用存疑。
研究设计与样本
- 研究纳入60具防腐尸体标本,随机分为实验组和对照组。
- 对照组采用不使用骨凿的标准胫骨截骨;实验组在标准技术基础上使用骨凿保留后交叉韧带胫骨附着处前方的骨岛。
主要发现
- 对照组后交叉韧带损伤率为73%(22/30)。
- 实验组后交叉韧带损伤率为23%(7/30)。
- 与不使用骨凿的对照组相比,使用骨凿的绝对风险降低为50%。
临床怎么用
- 作者认为,在手术经验有限时,交叉韧带保留型全膝关节置换术中可采用骨凿形成骨岛以保护后交叉韧带。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Prior studies have shown that the posterior cruciate ligament (PCL) may be partially resected during cruciate retaining (CR) total knee arthroplasty (TKA) using highly experienced hands and standard surgical technique; therefore, proper surgical technique is aimed at preservation and balance of the PCL during CR TKA. The central objective of this study is to evaluate the effectiveness of a simple surgical technique to prevent PCL damage during performance of a CR TKA. METHODS: Sixty embalmed cadaver specimens were randomized into 2 groups, experimental and control. The control group consisted of standard tibial resection without the use of an osteotome. The experimental group utilized an osteotome in addition to standard technique to preserve a bone island anterior to the tibial attachment of the PCL. RESULTS: In the control group, PCL damage was noted in 73% (22/30) of specimens. In the experimental group, where an osteotome was used, PCL damage was found in 23% (7/30) of specimens. The use of an osteotome was found to have an absolute risk reduction of 50% when compared to the control group which did not use an osteotome to protect the PCL. CONCLUSION: In the setting of minimal surgical experience, the use of an osteotome to preserve the PCL during CR TKA by forming a bone island was found to be an effective means of protecting the PCL over standard technique. In addition, standard technique with the use of a Y-shaped PCL retractor was found to provide questionable protection to the PCL.
引用
- Wood AR, Rabbani TA, Sheffer B, et al. Protecting the PCL During Total Knee Arthroplasty Using a Bone Island Technique. J Arthroplasty. 2017. PMID: 28927647. doi:10.1016/j.arth.2017.08.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。