血液金属离子水平在无症状大头金属对金属全髋关节置换术后监测中的效用有限
研究纳入256例股骨头直径≥36 mm的单侧金属对金属全髋关节置换术患者,前瞻性收集12年系列血钴(Co)和铬(Cr)离子水平,按英国药品和健康产品管理局(MHRA)指南每年随访检测。结果显示,在7 μg/L阈值下,Co和Cr预测金属碎屑不良反应(ARMD)的判别能力均较差,无症状患者7年后Co值无显著变化、Cr值在9年后下降。作者认为,在无症状患者中,每年检测血Co和Cr对诊断金属沉积的判别能力有限,7年后检测效用有限。
要点
- 在7 μg/L阈值下,血Co和Cr预测ARMD的ROC曲线判别能力均较差。
- Co敏感性82.1%、阳性预测值43.8%;Cr敏感性53.5%、阳性预测值67.6%。
- 无症状患者7年后Co值无显著变化,Cr值在9年后下降。
核心结论
- 作者认为,在无症状大头金属对金属全髋关节置换术患者中,每年检测血Co和Cr对诊断金属沉积的判别能力有限,7年后检测效用有限。
研究设计与样本
- 前瞻性纳入256例股骨头直径≥36 mm的单侧金属对金属全髋关节置换术患者,植入物为Birmingham髋表面置换杯-Freeman柄(BHR-F)或Articular Surface Resurfacing杯-Corail/S-ROM柄。
- 按英国药品和健康产品管理局(MHRA)指南每年随访检测血Co和Cr,并基于敏感性和特异性绘制受试者工作特征(ROC)曲线以检测ARMD,无症状患者单独分析。
主要发现
- ROC曲线显示,在7 μg/L阈值下,Co和Cr对预测ARMD的判别能力均较差。
- Co敏感性82.1%、阳性预测值43.8%;Cr敏感性53.5%、阳性预测值67.6%。
- 无症状患者7年后Co值无显著变化,Cr值在9年后下降。
关键数值与推荐
- 血Co和Cr预测ARMD的阈值评估为7 μg/L。
- Co敏感性82.1%、阳性预测值43.8%;Cr敏感性53.5%、阳性预测值67.6%。
临床怎么用
- 作者建议,在无症状大头金属对金属全髋关节置换术患者中,每年血Co和Cr检测的判别能力有限,7年后检测效用有限。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Blood cobalt (Co) and chromium (Cr) ion levels have been used as surveillance tools for adverse reaction to metal debris (ARMD) in metal-on-metal (MoM) articulations with varying thresholds in different countries. The aim of our study is to present the serial 12-year blood Co and Cr levels in a cohort of MoM total hip arthroplasties (THAs) with femoral head size ≥36 mm and analyze their utility in asymptomatic patients at current thresholds. METHODS: A total of 256 patients with unilateral MoM THA with femoral head size ≥36 mm were included in this study with data collected prospectively. The implants used were Birmingham hip resurfacing cup-Freeman stem (BHR-F) or an Articular Surface Resurfacing cup-Corail/S-ROM stem. Annual follow-up with blood Co and Cr measurements was done as per Medicines and Healthcare Products Regulatory Agency (MHRA) of the United Kingdom guidelines. Receiver operating characteristic curve was plotted based on the sensitivity and specificity of blood metal ion values to detect ARMD. The metal ion levels in asymptomatic patients were analyzed separately. RESULTS: Receiver operating characteristic curves showed poor discriminatory ability for both Co and Cr values in predicting ARMD at 7 μg/L. The sensitivity of Co and Cr was 82.1% and 53.5%, respectively, and their positive predictive values were 43.8% and 67.6%, respectively. After 7 years, there was no significant change in Co values, and there was a decline in Cr value after 9 years in asymptomatic patients. CONCLUSION: To the best of our knowledge, this is the first study to describe the behavior of serial blood metal ion levels in asymptomatic large-diameter MoM THA. We suggest that annual blood Co and Cr have limited discriminant capacity in diagnosing the occurrence of metallosis and their measurement beyond 7 years is of limited utility in asymptomatic patients.
引用
- Kiran M, Armstrong C, Shivarathre D, et al. Blood Metal Ion Levels Have Limited Utility in the Surveillance of Asymptomatic Large-Head Metal-on-Metal Total Hip Arthroplasties. J Arthroplasty. 2017. PMID: 28781016. doi:10.1016/j.arth.2017.07.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。