三名Camurati-Engelmann病同胞的骨密度与骨材料强度指数不一致

Discrepancy between bone density and bone material strength index in three siblings with Camurati-Engelmann disease.
PubMed 文献 · Osteoporos Int · 2017-08-25

本文报告三名Camurati-Engelmann病同胞,采用双能X线吸收法测骨密度和骨小梁评分,用骨冲击微压痕测骨材料强度指数。三人骨密度均高、骨小梁评分正常,但骨材料强度指数低或极低,提示骨质量受损。

要点

  • 三名同胞骨密度均高(腰椎与髋部Z值之和>4),骨小梁评分正常。
  • 骨材料强度指数低于或远低于正常对照,与高骨密度不一致。
  • 作者认为微压痕或可用于评估此类患者的骨脆性。

核心结论

  • 尽管骨密度显著增高且微结构正常,Camurati-Engelmann病患者的骨材料强度指数仍受影响。
  • 微压痕或可作为评估这类患者骨脆性的合适工具。
  • 该类患者的骨病需进一步研究以更好理解潜在调控机制及其改变。

研究设计与样本

  • 对三名Camurati-Engelmann病同胞进行临床资料采集和一般实验室检查。
  • 用双能X线吸收法测量腰椎和髋部骨密度及骨小梁评分。
  • 用Osteoprobe仪器经骨冲击微压痕测量骨材料强度指数。

主要发现

  • 三例骨密度值均符合高骨量(腰椎与髋部Z值之和>4)。
  • 三例同胞全髋和股骨颈骨密度均极高,腰椎骨密度两例正常、第三例极高。
  • 骨小梁评分均在正常范围。
  • 与正常对照相比,骨材料强度指数处于低或极低水平。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文指出该类患者骨特征数据有限。
  • 原文结论提出该类患者骨病需进一步研究以更好理解潜在调控机制及其改变。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: Camurati-Engelmann (CE) is a very rare disease affecting one in every million persons worldwide. It is characterized by an enlargement of long bones. We aimed to assess bone characteristics in three siblings with different tools. Even if there was an excess of bone density, quality seemed to be deteriorated. INTRODUCTION: CE disease is a rare monogenic disorder affecting approximately one in every million persons worldwide. It is mainly characterized by a progressive hyperostosis of the periosteum and endosteum of the diaphysis of long bones. Limited data are available about bone characteristics in these patients. In three siblings with CE disease, we aimed to assess bone mineral density (BMD) and trabecular bone score (TBS) by dual-energy X-ray absorptiometry (DXA) and material characteristics at tissue level using bone impact reference point indentation. METHODS: Clinical data were collected and a general laboratory workup was performed. At the lumbar spine and hip, BMD and TBS were measured using DXA imaging. Bone material strength index (BMSi) was measured by bone impact microindentation using an Osteoprobe instrument. RESULTS: All three cases had densitometric values consistent with high bone mass (sum of Z-score at the lumbar spine and hip > 4). Hip BMD was extremely high in all three siblings at both total hip and femoral neck, while at the lumbar spine, two of them had normal values but the third again had very high BMD. TBS values were in the normal range. In contrast, BMSi measurements were at low or very low levels, compared with normal controls. CONCLUSION: Despite strikingly increased BMD and normal microarchitecture, BMSi is affected in patients with CE. Microindentation could be an appropriate tool for assessing bone fragility in these patients. Bone disease in this group of patients requires further study to better understand the underlying regulatory mechanisms and their alterations.