亚甲蓝引导的清创作为假体周围关节感染手术治疗的术中辅助手段
前瞻性研究纳入16例符合美国肌肉骨骼感染学会(MSIS)假体周围关节感染(PJI)标准、接受第一阶段二期翻修置换术的全膝关节置换患者,术中采用0.1%亚甲蓝染色引导清创,比较染色与未染色组织的细菌负荷。染色组织半定量培养细菌更多(P=.001),葡萄球菌属PCR生物负荷为未染色的9倍(P=.02),染色组织每高倍视野中性粒细胞53±46 vs 未染色4±13(P=.0001)。全部患者清除主要感染并完成再植入,平均2年随访时25%因不同微生物的新发感染而失败。
要点
- 亚甲蓝染色组织半定量培养细菌较未染色组织更多(P=.001)。
- 染色组织葡萄球菌属PCR生物负荷为未染色组织的9倍(P=.02)。
- 全部16例清除主要感染并再植入,平均2年随访25%因不同微生物新发感染失败。
核心结论
- 结果提示亚甲蓝可为假体周围关节感染治疗中的手术清创提供视觉指示。
研究设计与样本
- 前瞻性研究纳入16例符合肌肉骨骼感染学会(MSIS)假体周围关节感染标准、接受第一阶段二期翻修置换术的全膝关节置换患者。
- 术中将稀释亚甲蓝(0.1%)注入膝关节后清创,清除残留染料并切除染色组织。
- 清创过程中从股骨、胫骨和关节囊采集配对的染色与未染色组织样本,行中性粒细胞计数、半定量培养和定量聚合酶链反应(PCR)分析。
- 临床成功为次要结局。
主要发现
- 平均年龄64.0±6.0岁,随访24.4±3.5个月。
- 基于半定量培养,亚甲蓝染色组织较未染色组织发现更多细菌(P=.001)。
- 葡萄球菌属PCR显示亚甲蓝染色组织生物负荷为未染色组织的9倍(P=.02)。
- 组织病理学显示亚甲蓝染色组织每高倍视野多形核白细胞为53±46,未染色组织为4±13(P=.0001)。
- 所有受试者清除主要感染并接受再植入;平均2年随访时25%患者因不同微生物的新发感染而失败。
临床怎么用
- 原文未据此给出推荐。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Current methods to identify infected tissue in periprosthetic joint infection (PJI) are inadequate. The purpose of this study was (1) to assess methylene blue-guided surgical debridement as a novel technique in PJI using quantitative microbiology and (2) to evaluate clinical success based on eradication of infection and infection-free survival. METHODS: Sixteen total knee arthroplasty patients meeting Musculoskeletal Infection Society criteria for PJI undergoing the first stage of 2-stage exchange arthroplasty were included in this prospective study. Dilute methylene blue (0.1%) was instilled in the knee before debridement, residual dye was removed, and stained tissue was debrided. Paired tissue samples, stained and unstained, were collected from the femur, tibia, and capsule during debridement. Samples were analyzed by neutrophil count, semiquantitative culture, and quantitative polymerase chain reaction (PCR). Clinical success was a secondary outcome. RESULTS: The mean age was 64.0 ± 6.0 years, and follow-up was 24.4 ± 3.5 months. More bacteria were found in methylene blue-stained vs unstained tissue-based on semiquantitative culture (P = .001). PCR for staphylococcal species showed 9-fold greater bioburden in methylene blue-stained vs unstained tissue (P = .02). Tissue pathology found 53 ± 46 polymorphonuclear leukocytes per high-power field in methylene blue-stained vs 4 ± 13 in unstained tissue (P = .0001). All subjects cleared their primary infection and underwent reimplantation. At mean 2-year follow-up, 25% of patients failed secondary to new infection with a different organism. CONCLUSION: These results suggest a role for methylene blue in providing a visual index of surgical debridement in the treatment of PJI.
引用
- Shaw JD, Miller S, Plourde A, et al. Methylene Blue-Guided Debridement as an Intraoperative Adjunct for the Surgical Treatment of Periprosthetic Joint Infection. J Arthroplasty. 2017. PMID: 28811108. doi:10.1016/j.arth.2017.07.019