基于加速度计的可携式导航系统在全膝关节置换术中的应用价值
这项前瞻性随机对照研究纳入241例原发性膝骨关节炎患者,比较KneeAlign2导航系统与传统髓内导引在股骨远端截骨中的效果。KA2组121例,IM组120例。结果显示KA2组机械轴偏离超过3°者显著更少,失血量显著更少。
要点
- KA2组仅1例(0.8%)机械轴偏离超过3°,IM组19例,差异显著(p<0.01)。
- KA2组平均偏离1.01°(标准差1.0°),IM组1.93°(标准差1.7°),差异显著(p<0.01)。
- KA2组失血量784 ml(标准差357),显著少于IM组1071 ml(标准差310),p<0.001。
核心结论
- KneeAlign2系统为全膝关节置换术中识别股骨头并在股骨远端进行精确截骨提供了一种技术上简便的方法,且与传统髓内导引相比失血量显著更少。
研究设计与样本
- 前瞻性随机对照研究,连续纳入241例原发性膝骨关节炎患者,其中女性207例、男性34例,平均年龄74.0岁(范围57至89岁)。
- KA2组121例使用KneeAlign2系统进行股骨远端截骨,IM组120例使用传统髓内股骨导引。
主要发现
- KA2组1例(0.8%)机械轴偏离超过3°,IM组19例,差异有统计学意义(p<0.01)。
- KA2组平均偏离中立位1.01°(标准差1.0°),IM组1.93°(标准差1.7°),差异有统计学意义(p<0.01)。
- KA2组失血量784 ml(标准差357),IM组1071 ml(标准差310),KA2组显著少于IM组(p<0.001)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aim of this study was to evaluate the effects of using a portable, accelerometer-based surgical navigation system (KneeAlign2) in total knee arthroplasty (TKA) on the alignment of the femoral component, and blood loss. PATIENTS AND METHODS: A total of 241 consecutive patients with primary osteoarthritis of the knee were enrolled in this prospective, randomised controlled study. There were 207 women and 34 men. The mean age of the patients was 74.0 years (57 to 89). The KneeAlign2 system was used for distal femoral resection in 121 patients (KA2 group) and a conventional intramedullary femoral guide was used in 120 patients (IM group). RESULTS: One patient (0.8%) in the KA2 group and 19 in the IM group had an alignment which was > 3° away from the neutral mechanical axis (p < 0.01). The mean deviation from neutral alignment was 1.01° (standard deviation (sd) 1.0°) in the KA2 group and 1.93° (sd 1.7°) in the IM group (p < 0.01). Blood loss was significantly less in the KA2 group compared with the IM group (784 ml (sd 357) versus 1071 ml (sd 310), p < 0.001). CONCLUSION: The KneeAlign2 system provides a technically straightforward method for identifying the femoral head and performing an accurate distal femoral resection at TKA with significantly less blood loss compared with a conventional intramedullary guide. Cite this article: Bone Joint J 2017;99-B:1047-52.
引用
- Ikawa T, Takemura S, Kim M, et al. Usefulness of an accelerometer-based portable navigation system in total knee arthroplasty. Bone Joint J. 2017. PMID: 28768781. doi:10.1302/0301-620X.99B8.BJJ-2016-0596.R3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。