文献速递关节外科

多孔钽干骺端锥形套在翻修全膝关节置换术中是否改善结局?

Do Porous Tantalum Metaphyseal Cones Improve Outcomes in Revision Total Knee Arthroplasty?
PubMed 文献 · J Arthroplasty · 2017-07-28

本研究将49例使用多孔钽干骺端锥形套(39例仅胫骨、3例仅股骨、7例两者均用)的翻修全膝关节置换术患者按手术指征匹配至49例使用传统混合柄技术(非锥形套)的患者,在至少两年随访(平均3.5年)时比较临床与影像学结局。非锥形套组在膝关节学会评分(37.2±18.6 vs 28.4±17.8,P=0.010)和膝关节学会功能评分(30.4±24.3 vs 13.1±27.6,P=0.003)上的术前至术后改善幅度更大。两组在并发症、再手术、再翻修、患者满意度及多项影像学指标上无差异。

要点

  • 非锥形套组膝关节学会评分改善幅度大于锥形套组(37.2±18.6 vs 28.4±17.8,P=0.010)。
  • 非锥形套组膝关节学会功能评分改善幅度大于锥形套组(30.4±24.3 vs 13.1±27.6,P=0.003)。
  • 两组在并发症、再手术、再翻修、满意度及影像学指标上无显著差异。

核心结论

  • 在本系列中,干骺端锥形套在短期随访时未与更优结局相关。
  • 鉴于使用锥形套较传统技术成本增加,本研究不能支持在翻修全膝关节置换术中常规使用干骺端锥形套。
  • 需要更长期随访以确定长期结构耐久性是否存在差异。

研究设计与样本

  • 将49例使用股骨和/或胫骨干骺端锥形套(39例仅胫骨、3例仅股骨、7例两者均用)的翻修全膝关节置换术患者按手术指征匹配至49例使用传统混合柄(非锥形套)技术的翻修全膝关节置换术患者。
  • 在至少两年随访(平均3.5年)时比较临床与影像学结局,并对基线特征进行调整。

主要发现

  • 翻修前骨缺损和大多数基线人口学特征在锥形套组与非锥形套组之间相似,提示匹配适当。
  • 非锥形套组膝关节学会评分术前至术后增加幅度大于锥形套组(37.2±18.6 vs 28.4±17.8,P=0.010)。
  • 非锥形套组膝关节学会功能评分术前至术后增加幅度大于锥形套组(30.4±24.3 vs 13.1±27.6,P=0.003)。
  • 两组在并发症、后续再手术、后续再翻修、患者满意度、胫骨悬突、放射性硬化线、柄周围皮质肥厚或胫骨下沉方面无差异。

临床怎么用

  • 作者认为,鉴于锥形套较传统技术成本增加,本研究不能支持在翻修全膝关节置换术中常规使用干骺端锥形套。

局限性

  • 需要更长期随访以确定长期结构耐久性是否存在差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Some authors have advocated for use of porous tantalum metaphyseal cones to manage bone defects during revision total knee arthroplasty (TKA). The purpose of this study is to compare results with porous metaphyseal cones to results with traditional hybrid stem fixation in revision TKA. METHODS: Forty-nine patients undergoing revision TKA with femoral and/or tibial metaphyseal cones (39 tibial only, 3 femoral only, 7 both) were matched by surgical indication to 49 patients undergoing revision TKA with a traditional hybrid stem (non-cone) technique. Clinical and radiographic outcomes were compared at a minimum of two-year follow-up (mean 3.5 years) with adjustment for baseline characteristics. RESULTS: Pre-revision bone defects and most baseline demographics were similar between the cone and non-cone cohorts suggesting appropriate matching. Patients in the non-cone cohort had greater pre- to post-operative increases in Knee Society Score (37.2 ± 18.6 vs 28.4 ± 17.8, P = .010) and Knee Society Functional Score (30.4 ± 24.3 vs 13.1 ± 27.6, P = .003). The cohorts did not differ with respect to complications, subsequent reoperation, subsequent revision, patient satisfaction, tibial overhang, the presence of radio-sclerotic lines, cortical hypertrophy around the stems, or tibial subsidence. CONCLUSION: In this series, metaphyseal cones were not associated with superior outcomes at short-term follow-up. Given the increased cost associated with use of cones compared to traditional techniques, this study cannot support the routine use of metaphyseal cones in revision TKA. Longer-term follow-up will be necessary to determine if construct durability differs over the long term.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Bohl DD, Brown NM, McDowell MA, et al. Do Porous Tantalum Metaphyseal Cones Improve Outcomes in Revision Total Knee Arthroplasty? J Arthroplasty. 2017. PMID: 28844630. doi:10.1016/j.arth.2017.07.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。