使用一体式带脊锥形喷砂钛柄行翻修全髋关节置换术
单外科医生回顾性分析68例(67例患者)使用非模块化带脊锥形股骨柄行翻修全髋关节置换术,随访至少2年,85%病例Paprosky分型3A或以上。Harris髋关节评分从术前37.4±19.4改善至末次随访64.6±21.8(P<.001)。4年随访时全因翻修生存率72.9%(95%CI 57.0-83.8),无菌性股骨翻修生存率95.5%(95%CI 86.8-98.5)。
要点
- Harris髋关节评分从术前37.4±19.4改善至末次随访64.6±21.8(P<.001)。
- 骨长入除4例患者外均观察到(94.1%),下沉率3.0%,脱位率7.4%。
- 4年随访全因翻修生存率72.9%(95%CI 57.0-83.8),无菌性股骨翻修生存率95.5%(95%CI 86.8-98.5)。
核心结论
- 尽管并发症显著,因股骨无菌性松动行翻修仅3例患者。
- 鉴于该一体式带脊锥形柄能在复杂翻修全髋关节置换术中提供充分固定,在股骨骨缺损严重时仍是一种可行选择。
研究设计与样本
- 回顾性分析单外科医生使用非模块化带脊锥形股骨柄行翻修全髋关节置换术的结局,随访至少2年,共68例(67例患者)。
- 85%的病例Paprosky分型为3A或以上。
主要发现
- Harris髋关节评分从术前37.4±19.4改善至末次随访64.6±21.8(P<.001)。
- 共16例翻修手术,其中8例为感染指征,8例为无菌指征。
- 下沉发生率为3.0%,脱位率为7.4%。
- 翻修后下肢长度差异超过1 cm见于13.6%的患者。
- 除4例患者外均观察到骨长入(94.1%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In revision total hip arthroplasty (THA), proximal femoral bone loss creates a challenge of achieving adequate stem fixation. The purpose of this study was to examine the outcomes of a monoblock, splined, tapered femoral stem in revision THA. METHODS: Outcomes of revision THA using a nonmodular, splined, tapered femoral stem from a single surgeon were reviewed. With a minimum of 2-year follow-up, there were 68 cases (67 patients). Paprosky classification was 3A or greater in 85% of the cases. Preoperative and postoperative Harris Hip Scores (HHS), radiographic subsidence and osseointegration, limb length discrepancy, complications, and reoperations were analyzed. RESULTS: The Harris Hip Score improved from 37.4 ± SD 19.4 preoperatively to 64.6 ± SD 21.8 at final follow-up (P < .001). There were 16 revision procedures-8 for septic indications and 8 for aseptic indications. Subsidence occurred at a rate of 3.0% and dislocation at 7.4%. Limb length discrepancy of more than 1 cm after revision was noted in 13.6% of patients. Bone ingrowth was observed in all but 4 patients (94.1%). At 4-year follow-up, Kaplan-Meier estimated survival was 72.9% (95% confidence interval [CI] 57.0-83.8) for all causes of revision, 86.6% (95% CI 72.0-93.9) for all aseptic revision, and 95.5% (95% CI 86.8-98.5) for aseptic femoral revision. CONCLUSION: Although complications were significant, revision for femoral aseptic loosening occurred in only 3 patients. Given the ability of this monoblock splined tapered stem to adequately provide fixation during complex revision THA, it remains a viable option in the setting of substantial femoral bone defects.
引用
- Hellman MD, Kearns SM, Bohl DD, et al. Revision Total Hip Arthroplasty With a Monoblock Splined Tapered Grit-Blasted Titanium Stem. J Arthroplasty. 2017. PMID: 28803814. doi:10.1016/j.arth.2017.06.045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。