文献速递关节外科

将限制性内衬骨水泥固定于牢固的非骨水泥髋臼壳:至少15年随访研究

Cementing Constrained Liners Into Secure Cementless Shells: A Minimum 15-Year Follow-Up Study.
PubMed 文献 · J Arthroplasty · 2017-07-18

本研究报道同一队列至少15年随访结果:1988至2000年间在3家机构将31个连续的限制性内衬骨水泥固定于固定良好、位置良好的非骨水泥髋臼壳,平均年龄72岁,16例因复发性髋关节脱位、15例因术中不稳定。至少15年随访时1例失访,3髋(9.7%)因装置失败翻修,5髋(16.1%)因任何原因翻修。作者认为考虑到病例复杂性,该构型具有优异的中期耐久性。

要点

  • 31个连续限制性内衬骨水泥固定于固定良好、位置良好的非骨水泥髋臼壳。
  • 至少15年随访:1例失访,3髋(9.7%)因装置失败翻修,5髋(16.1%)因任何原因翻修。
  • 作者认为考虑病例复杂性,该构型具有优异的中期耐久性。

核心结论

  • 在至少15年随访时,考虑到病例的复杂性,该构型具有优异的中期耐久性。

研究设计与样本

  • 1988年至2000年间,在3家机构将31个连续的同一种设计的限制性内衬骨水泥固定于固定良好、位置良好的非骨水泥髋臼壳。
  • 手术时平均年龄72岁(范围31-91岁)。
  • 手术指征为复发性髋关节脱位16例和术中不稳定15例。
  • 评估因装置失败翻修和因任何原因翻修。

主要发现

  • 至少15年随访时,1例患者失访。
  • 3髋(9.7%)因装置失败翻修。
  • 5髋(16.1%)因任何原因翻修。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The authors and others have previously described the technique of cementing constrained liners into secure cementless acetabular shells and reported the short-term, average 3.9-year follow-up, using that technique. The purpose of the present study was to report the minimum 15-year follow-up of this same cohort. METHODS: Between 1988 and 2000, 31 consecutive constrained liners of one design were cemented into well-fixed, well-positioned cementless acetabular shells at 3 institutions. Average age at surgery was 72 years (range, 31-91 years). Indications for the procedure were recurrent hip dislocation in 16 cases and intraoperative instability in 15 cases. Patients were evaluated for revision for failure of the device and revision for any reason. RESULTS: At minimum 15-year follow-up, there was 1 patient lost to follow-up. Three hips (9.7%) were revised for failure of the device and 5 hips (16.1%) were revised for any reason. CONCLUSION: At minimum 15-year follow-up, considering the complexity of cases, there was excellent medium-term durability of this construct.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Young GH, Abdel MP, Amendola RL, et al. Cementing Constrained Liners Into Secure Cementless Shells: A Minimum 15-Year Follow-Up Study. J Arthroplasty. 2017. PMID: 28780226. doi:10.1016/j.arth.2017.07.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。