4573例脊柱手术中耐甲氧西林金黄色葡萄球菌鼻腔拭子与吸引引流管尖端培养:对手术部位感染管理的效用
该回顾性单中心研究纳入2008年1月至2014年12月4573例连续脊柱手术患者,评估MRSA鼻腔拭子与引流管尖端培养对手术部位感染的诊断价值。结果显示MRSA鼻腔拭子培养阳性组与阴性组SSI阳性率无显著差异,引流管尖端培养阳性组与阴性组SSI阳性率有显著差异,引流管尖端培养灵敏度29.8%、特异度92.1%。作者结论认为两者均不能有效预测SSI,但引流管尖端培养在SSI组阳性率高且致病菌符合率较高。
要点
- MRSA鼻腔拭子培养阳性组与阴性组SSI阳性率无显著差异,不能预测SSI。
- 引流管尖端培养阳性组与阴性组SSI阳性率有显著差异,灵敏度29.8%、特异度92.1%。
- 引流管尖端培养阳性且发生SSI的28例中16例手术部位分离出相同细菌,符合率57.1%。
核心结论
- MRSA鼻腔拭子和引流管尖端培养对预测手术部位感染均无实用价值。
- 但引流管尖端培养在手术部位感染组阳性率高,且致病菌符合率相对较高。
研究设计与样本
- 回顾性单中心研究,纳入2008年1月至2014年12月间接受脊柱手术的4573例连续患者,排除诊断为感染性疾病的患者。
- 术中及术后预防性使用抗生素48小时,所有患者术前均采集MRSA鼻腔拭子培养。
- 术后引流量在之前24小时内少于50 mL时拔除引流管并做尖端培养,手术部位感染按美国疾病控制与预防中心标准定义。
主要发现
- 手术部位感染94例(2.1%),其中87例(92.6%)分离出细菌。
- MRSA鼻腔拭子培养阳性49例(1.1%),MRSA鼻腔拭子培养阳性组与阴性组手术部位感染阳性率无显著差异。
- 引流管尖端培养阳性382例(8.4%),其中28例发生手术部位感染,引流管尖端培养阳性组与阴性组手术部位感染阳性率有显著差异。
- 引流管尖端培养灵敏度29.8%、特异度92.1%。
- 引流管尖端培养阳性且发生手术部位感染的28例中,16例从手术部位分离出相同细菌,细菌符合率57.1%。
关键数值与推荐
- 手术部位感染按美国疾病控制与预防中心标准定义。
- 引流管拔除标准为之前24小时引流量少于50 mL。
- 预防性抗生素于术中及术后使用48小时。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: A retrospective single-center study. OBJECTIVE: To assess the diagnostic value of methicillin-resistant Staphylococcus aureus (MRSA) nasal swab and suction drain tip cultures. SUMMARY OF BACKGROUND DATA: The prognostic value of MRSA nasal swab and suction drain tip cultures has not been firmly established in spinal surgery. METHODS: This study retrospectively included 4573 consecutive patients who underwent spinal surgery between January 2008 and December 2014. Patients diagnosed with infectious disease were excluded. Prophylactic antibiotics were administered intraoperatively and postoperatively for 48 hours. MRSA nasal swab cultures were taken from all patients before surgery. Drains were removed when the volume of postoperative fluid drainage was less than 50 mL in the preceding 24 hours and cultures were made. Surgical site infection (SSI) was defined according to Centers for Disease Control and Prevention criteria. RESULTS: SSI was identified in 94 cases (2.1%) and bacteria were isolated in 87 cases (92.6%). Positive MRSA nasal swab cultures were identified in 49 cases (1.1%). There was no significant difference in the SSI positivity rate between the MRSA nasal swab culture (+) and (-) groups. Positive drain tip cultures were found in 382 cases (8.4%), 28 of which developed SSI. There was a significant difference in the SSI positivity rate between the drain tip culture (+) and (-) groups. The sensitivity of drain tip culture was 29.8% and the specificity was 92.1%. In 16 of the 28 patients in the SSI (+) group with positive drain cultures, the same bacteria were isolated from the surgical site, giving a bacteria matching rate of 57.1%. CONCLUSION: MRSA nasal swab and drain tip cultures were not useful for predicting SSI. However, drain tip culture had a high positivity rate in the SSI group and the coincidence rate for the causative pathogen was relatively high. LEVEL OF EVIDENCE: 4.
引用
- Kawabata A, Sakai K, Sato H, et al. Methicillin-Resistant Staphylococcus aureus Nasal Swab and Suction Drain Tip Cultures in 4573 Spinal Surgeries: Efficacy in Management of Surgical Site Infections. Spine (Phila Pa 1976). 2018. PMID: 28767628. doi:10.1097/BRS.0000000000002360
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。