文献速递脊柱外科骨质疏松与代谢性骨病创伤骨科

椎体骨折评估(VFA)与常规脊柱X线摄影相比的价值与潜在局限性:来自骨折联络服务(FLS)的经验及一项Meta分析

Value and potential limitations of vertebral fracture assessment (VFA) compared to conventional spine radiography: experience from a fracture liaison service (FLS) and a meta-analysis.
PubMed 文献 · Osteoporos Int · 2017-08-25

该研究通过回顾性诊断研究(542例骨折患者)和系统综述与Meta分析(16项研究,3238名受试者)评估VFA识别椎体骨折的性能。Meta分析汇总敏感度0.84、特异度0.90,但本中心未重现该性能;作者建议在完全依赖VFA前先核查其性能。

要点

  • 本中心VFA检测≥Genant 2级椎体骨折的敏感度0.77、特异度0.80,与Meta分析汇总值有差距。
  • Meta分析汇总VFA检测≥Genant 2级椎体骨折的敏感度0.84(95%CI 0.72-0.92)、特异度0.90(95%CI 0.84-0.94)。
  • 作者建议在完全依赖VFA评估椎体骨折前,先核查该技术的性能和潜在局限性。

核心结论

  • Meta分析结果提示VFA检测椎体骨折的性能 adequate,但本中心未能证实该表现,尤其是特异度。
  • 作者建议在没有明确VFA的性能和潜在局限性之前,谨慎地完全依赖VFA评估椎体骨折。

研究设计与样本

  • 回顾性诊断研究:纳入542例发生过骨折的患者(25%为男性),评估低辐射VFA与常规脊柱X线摄影相比检测椎体骨折的性能。
  • 系统综述与Meta分析:检索并纳入16项研究,共3238名受试者(19%为男性),平均年龄范围45至74岁;同时进行偏倚风险分析。

主要发现

  • 本中心诊断研究中,低辐射VFA检测≥Genant 2级椎体骨折患者的敏感度为0.77,特异度为0.80。
  • 本中心诊断研究中,297例(55%)患者有≥1个不可评估椎体,135例(25%)有≥3个不可评估椎体。
  • Meta分析中,7项研究偏倚风险低,9项为中等风险,主要因未连续纳入患者。
  • Meta分析汇总VFA检测≥Genant 2级椎体骨折患者的敏感度为0.84(95%CI 0.72-0.92),特异度为0.90(95%CI 0.84-0.94)。

临床怎么用

  • 作者建议在完全依赖VFA评估椎体骨折之前,先核查VFA工具的性能和潜在局限性。

局限性

  • 本中心未能证实Meta分析中VFA的 adequate 性能,尤其是特异度。
  • Meta分析纳入的16项研究中,9项存在中等偏倚风险,主要因未连续纳入患者。
  • 本中心诊断研究为回顾性研究。
  • 作者建议在完全依赖VFA前核查其性能和潜在局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: We evaluated the value of VFA in the identification of vertebral fractures using a retrospective study and a meta-analysis. Performance of VFA was adequate in the meta-analysis although this was not demonstrated in our centre. We recommend checking the performance of VFA tools before exclusively relying on this tool. INTRODUCTION: Vertebral fractures are traditionally diagnosed using conventional radiographs of the spine. Vertebral fracture assessment (VFA) has been advocated as an alternative tool in the diagnosis of these fractures. METHODS: We conducted a retrospective study as well as a systematic review and a meta-analysis to evaluate the performance of VFA compared to conventional spinal radiography in patients who had sustained a fracture and thus at risk for osteoporosis. A risk of bias analysis was also performed. RESULTS: The diagnostic study included 542 patients (25% male) with fractures. The sensitivity of low-radiation VFA to detect a patient with a vertebral fracture ≥ Genant grade 2 was 0.77 and its specificity 0.80. Two hundred ninety-seven (55%) patients had ≥1 and 135(25%) ≥3 unevaluable vertebrae. The systematic review identified 16 studies including a total of 3238 subjects (19% male) with a mean age range of 45 to 74 years. Seven studies had a low risk of bias and 9 had an intermediate risk, mainly due to not consecutively including patients. The pooled sensitivity of VFA to detect a patient with a vertebral fracture ≥Genant grade 2 was 0.84 (95% CI, 0.72-0.92) and specificity 0.90 (95% CI, 0.84-0.94). CONCLUSIONS: Our findings from the meta-analysis suggest an adequate performance of VFA for the detection of vertebral fractures. However, we could not demonstrate these findings in our center, especially the specificity. Our data advocate caution with exclusively relying on VFA in the assessment of vertebral fractures without identifying performance and potential limitations of the technique.

来源:Osteoporos Int,查看原文。版权归原作者所有。

引用

  1. Malgo F, Hamdy NAT, Ticheler CHJM, et al. Value and potential limitations of vertebral fracture assessment (VFA) compared to conventional spine radiography: experience from a fracture liaison service (FLS) and a meta-analysis. Osteoporos Int. 2017. PMID: 28842721. doi:10.1007/s00198-017-4137-6