新型解剖形聚碳酸酯聚氨酯全半月板假体的体内性能:山羊12个月评估
研究在山羊模型中评估新型解剖形聚碳酸酯聚氨酯全半月板假体经12个月生理负载后的磨损、变形及软骨保护能力,并与同种异体移植、全半月板切除和假手术对照比较。假体磨损极小、变形有限,但1例因后角延伸部完全撕裂而失败;假体、同种异体移植与半月板切除组的软骨组织病理学状况无差异,但局部评分均显著差于未手术对照。作者认为假体耐磨且12个月负载后变形可接受,但需加强假体角部以防失败。
要点
- 假体关节面磨损极小,滑液中未见磨损颗粒,假体变形有限。
- 1例假体因后角延伸部完全撕裂而失败。
- 假体、同种异体移植与半月板切除组软骨组织病理学状况无差异,但局部评分均显著差于未手术对照。
核心结论
- 该新型假体耐磨,12个月生理负载后变形可接受,但需加强假体角部以防角部失败。
- 假体未能保护软骨免于退变,但同种异体移植组的损伤进展相似。
研究设计与样本
- 控制性实验室研究,对26只雌性萨能山羊的膝关节行手术,分为假体组、同种异体移植组、全半月板切除组和假手术组,假手术组对侧关节作为未手术对照。
- 随访12个月后评估假体磨损、变形及滑膜与软骨的组织病理学状况。
主要发现
- 假体关节面磨损极小,滑液中未见磨损颗粒,假体变形有限。
- 1例假体因后角延伸部完全撕裂而失败。
- 假体、同种异体移植与半月板切除组的软骨组织病理学状况无差异,但局部软骨评分均显著差于未手术对照。
临床怎么用
- 作者认为该新型聚碳酸酯聚氨酯假体可能成为有症状的全半月板切除患者的替代治疗选择。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Injury or loss of the meniscus generally leads to degenerative osteoarthritic changes in the knee joint. However, the treatment options for symptomatic patients with total meniscectomy are limited. Therefore, we developed a novel, anatomically shaped, total meniscal implant made of polycarbonate urethane. PURPOSE: To evaluate the in vivo performance of this novel total meniscal implant. The assessment particularly focused on the implant's response to long-term physiological loading in a goat model and its chondroprotective capacity in comparison to clinically relevant controls. STUDY DESIGN: Controlled laboratory study. METHODS: Surgery was performed to the stifle joint of 26 female Saanen goats, subdivided into 4 groups: implant, allograft, total meniscectomy, and sham surgery. The sham group's contralateral joints served as nonoperated controls. After 12 months of follow-up, investigators evaluated implant wear, deformation, and the histopathological condition of the synovium and cartilage. RESULTS: Wear of the implant's articulating surfaces was minimal, which was confirmed by the absence of wear particles in the synovial fluid. Implant deformation was limited. However, one implant failed by complete tearing of the posterior horn extension. No differences in cartilage histopathological condition were observed for the implant, allograft, and meniscectomy groups. However, locally, the cartilage scores for these groups were significantly worse than those of the nonoperated controls. CONCLUSION: Whereas this study demonstrated that the novel implant is resistant to wear and that deformation after 12 months of physiological loading is acceptable, reinforcement of the implant horns is necessary to prevent horn failure. Although the implant could not protect the cartilage from developing degenerative changes, the progression of damage was similar in the allograft group. CLINICAL RELEVANCE: This novel polycarbonate urethane implant may have the potential to become an alternative treatment for symptomatic patients with total meniscectomy.
引用
- Vrancken ACT, Hannink G, Madej W, et al. In Vivo Performance of a Novel, Anatomically Shaped, Total Meniscal Prosthesis Made of Polycarbonate Urethane: A 12-Month Evaluation in Goats. Am J Sports Med. 2017. PMID: 28719787. doi:10.1177/0363546517713687
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。