全膝关节置换术中关节腔内应用氨甲环酸比静脉应用更有效:一项前瞻性随机对照试验
研究将150例初次单侧全膝关节置换术患者随机分为静脉组、关节腔组和对照组(每组50例),分别给予氨甲环酸1g静脉+50mL关节腔生理盐水、1g关节腔+50mL关节腔生理盐水、0g+50mL关节腔生理盐水。结果显示关节腔组较静脉组减少更多总失血量(P=0.011)和术后48小时引流量(P<0.001),但隐性失血量三组无显著差异。结论认为关节腔应用氨甲环酸在减少总失血和引流量方面优于静脉应用,但未减少隐性失血。
要点
- 关节腔应用氨甲环酸较静脉应用显著减少总失血量(P=0.011)和48小时引流量(P<0.001)。
- 隐性失血量对照组、静脉组、关节腔组分别为708.6±308.2、651.7±302.9、625.2±252.1 mL,三组无显著差异。
- 静脉组和对照组各有2例接受输血,无深静脉血栓或其他严重并发症发生。
核心结论
- 全膝关节置换术中关节腔应用氨甲环酸较静脉注射显著更大程度地减少总失血量和引流量,但未减少隐性失血量。
研究设计与样本
- 前瞻性随机对照试验,共纳入150例初次单侧全膝关节置换术患者,随机分为静脉组、关节腔组和对照组,每组50例。
主要发现
- 关节腔组较静脉组减少更多总失血量(P=0.011)。
- 关节腔组较静脉组减少更多术后48小时引流量(P<0.001)。
- 隐性失血量对照组为708.6±308.2 mL、静脉组为651.7±302.9 mL、关节腔组为625.2±252.1 mL,三组无显著差异;分别占总失血量的65.6%、70.8%、81.1%。
- 静脉组和对照组各有2例接受输血。
- 无深静脉血栓或其他严重并发症发生。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The optimal administration route of tranexamic acid (TXA) in total knee arthroplasty (TKA), and the effect of TXA on hidden blood loss and total blood loss are undetermined. The purpose of this study was to compare the effectiveness of intravenous versus intra-articular application of tranexamic acid in patients undergoing knee arthroplasty. METHODS: A total of 150 patients undergoing primary unilateral total knee arthroplasty were randomly distributed to 3 groups (IV, intra-articular, and control group; each 50 patients) and administrated TXA (1 g IV and 50 mL intra-articular saline, 1 g intra-articularly and 50 mL intra-articular saline, and 0 g and 50 mL intra-articular saline, respectively). The amount of total and hidden blood loss (HBL), drainage, transfusion, changes in hemoglobin levels, and complications were recorded. RESULTS: Intra-articular use of TXA reduced more total blood loss (P = .011) and reduced more total 48 hours drainage volume than IV use of TXA (P < .001). Two patients received transfusion in IV and control group. No deep venous thrombosis or other severe complications had occurred. The HBL volume had no significant difference among the control, IV, and intra-articular groups (708.6 ± 308.2, 651.7 ± 302.9, and 625.2 ± 252.1 mL, respectively; which was 65.6%, 70.8%, and 81.1% of the total loss). CONCLUSION: Intra-articular administration of TXA significantly reduced total blood loss and drainage volume to a greater degree than IV injection in total knee arthroplasty without reduction of HBL.
引用
- Wang J, Wang Q, Zhang X, et al. Intra-articular Application is More Effective Than Intravenous Application of Tranexamic Acid in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial. J Arthroplasty. 2017. PMID: 28697863. doi:10.1016/j.arth.2017.06.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。