全髋关节翻修术中应用骨小梁金属髋臼假体的早期结果良好:一项前瞻性随机试验中42例髋臼翻修病例的放射立体测量随访

Promising early results for trabecular metal acetabular components used at revision total hip arthroplasty: 42 acetabular revisions followed with radiostereometry in a prospective randomised trial.
PubMed 文献 · Bone Joint J · 2017-01-01

这项前瞻性随机试验纳入42例髋臼翻修联合打压植骨患者,随机接受全聚乙烯骨水泥髋臼假体(19例)或骨小梁金属(TM)髋臼假体(23例),采用放射立体测量分析随访至术后两年或再次翻修。结果显示骨水泥组近端迁移显著更高,术后两年中位近端迁移骨水泥组为1.45 mm、TM组为0.25 mm(p=0.02);骨水泥组1例因脱位翻修,TM组无翻修。作者认为TM组近端迁移更低,提示该设计长期无菌性松动风险可能更低,但需更长随访确认临床优势。

要点

  • 术后两年中位近端迁移骨水泥组1.45 mm vs TM组0.25 mm(p=0.02),骨水泥组显著更高。
  • 骨水泥组1例因脱位翻修,TM组无翻修。
  • 作者认为TM组近端迁移更低,长期无菌性松动风险可能更低,但需更长随访确认。

核心结论

  • TM组近端迁移更低,提示该设计长期无菌性松动风险可能低于全聚乙烯骨水泥假体。
  • 需更长随访确认该假体在髋臼翻修中的临床优势。

研究设计与样本

  • 前瞻性随机试验,共纳入42例髋臼翻修联合打压植骨患者,随机接受全聚乙烯骨水泥髋臼假体(n=19)或骨小梁金属(TM)髋臼假体(n=23)。
  • 定期行放射立体测量分析与常规放射学检查,随访至术后两年或直至再次翻修。

主要发现

  • 术后两年中位近端迁移骨水泥组为1.45 mm vs TM组为0.25 mm(p=0.02),骨水泥组显著更高。
  • 骨水泥组1例假体因脱位翻修,TM组无翻修。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 需更长随访确认该假体的临床优势。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to compare the incidence of aseptic loosening after the use of a cemented acetabular component and a Trabecular Metal (TM) acetabular component (Zimmer Inc., Warsaw, Indiana) at acetabular revision with bone impaction grafting. PATIENTS AND METHODS: A total of 42 patients were included in the study. Patients were randomised to receive an all- polyethylene cemented acetabular component (n = 19) or a TM component (n = 23). Radiostereometric analysis and conventional radiographic examinations were performed regularly up to two years post-operatively or until further revision. RESULTS: The proximal migration was significantly higher in the cemented group. At two years, the median proximal migration was 1.45 mm and 0.25 mm in the cemented and TM groups, respectively (p = 0.02). One cemented component was revised due to dislocation. There were no revisions in the TM group. CONCLUSION: Lower proximal migration in the TM group suggests that this design might be associated with a lower risk of aseptic loosening in the long term compared with an all polyethylene cemented component. Longer follow-up is required to confirm the clinical advantages of using this component at acetabular revision. Cite this article: Bone Joint J 2017;99-B:880-6.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Mohaddes M, Shareghi B, Kärrholm J, et al. Promising early results for trabecular metal acetabular components used at revision total hip arthroplasty: 42 acetabular revisions followed with radiostereometry in a prospective randomised trial. Bone Joint J. 2017. PMID: 28663392. doi:10.1302/0301-620X.99B7.BJJ-2016-1241.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。