全髋关节置换术后站立位髋臼与股骨前倾角超出预设安全区
研究评估66例全髋关节置换患者术前术后三维EOS影像,测量骨盆与髋关节朝向。结果显示站立位髋臼与股骨假体朝向在多数患者中超出安全区,仰卧位定义的安全区可能不适用于评估存在显著骨盆倾斜患者的站立位X线片。
要点
- 站立位髋臼与股骨假体朝向在多数患者中超出仰卧位定义的安全区。
- 多数患者站立位前骨盆平面(APP)并非垂直,源于骨盆前倾或后倾。
- 仰卧位安全区可能不适用于评估站立位X线片,尤其存在显著骨盆倾斜者。
核心结论
- 站立位髋臼与股骨假体朝向在多数患者中位于安全区之外。
- 多数患者站立位前骨盆平面(APP)并非垂直,由骨盆前倾或后倾所致。
- 仰卧位提出的安全区在评估存在显著骨盆前倾或后倾患者的站立位X线片时可能不是有用的指标。
研究设计与样本
- 治疗性病例系列研究,证据等级IV级。
- 纳入66例全髋关节置换患者,评估术前与术后三维EOS影像。
- 随访期间(12-36个月)无患者发生脱位。
主要发现
- 髋臼前倾角术后在APP平面和患者功能平面均增加(P <.001)。
- 股骨颈前倾角术后降低(P =.0942)。
- 骶骨倾斜角术前42.4°(-25.9°至24°) vs 术后40.3°(-4.1°至64.2°),P =.013。
- 骨盆倾斜角从15.2°(-10.4°至43.8°)变为17.2°(-6°至46.7°),P = 0.008。
- 骨盆倾斜度术前1.12°(-25.9°至24°) vs 术后-1.2°(-40.7°至23.4°),P =.005。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although most hip dislocations occur in either standing or sitting position, the safe zone for implant position is defined for the supine position. Our goal was to determine preoperative and postoperative pelvis and hip orientations and whether the safe zone defined in supine position can be used to assess standing radiographs. METHODS: Preoperative and postoperative three-dimensional EOS images were assessed in 66 total hip arthroplasty patients. None of the patients had dislocation within the follow-up period (12-36 months). The acetabular anteversion (both anterior pelvic plane [APP] and patient functional plane) and the femoral anteversion were measured. The sacral slope, pelvic version, pelvic inclination, and pelvic incidence were also measured. RESULTS: Acetabular anteversion increased postoperatively in both APP and patient functional plane (P <.001). Femoral neck anteversion decreased postoperatively (P =.0942). Sacral slope was 42.4° (-25.9° to 24°) preoperatively compared with 40.3° (-4.1° to 64.2°) postoperatively (P =.013). Pelvic version changed from 15.2° (-10.4° to 43.8°) to 17.2° (-6° to 46.7°; P = 0.008). Pelvic inclination was 1.12° (-25.9° to 24°) before total hip arthroplasty and -1.2° (-40.7° to 23.4°) postoperatively (P =.005). CONCLUSION: The acetabular and femoral implant orientations in standing position reside out of the safe zone in most patients. The APP is not vertical in standing position in most patients due to anterior or posterior pelvic tilt. The proposed safe zone in supine position may not be a useful measure in the assessment of standing radiographs of patients with significant anterior or posterior pelvic tilt. LEVEL OF EVIDENCE: Level IV, therapeutic case series study.
引用
- Lazennec JY, Thauront F, Robbins CB, et al. Acetabular and Femoral Anteversions in Standing Position are Outside the Proposed Safe Zone After Total Hip Arthroplasty. J Arthroplasty. 2017. PMID: 28697862. doi:10.1016/j.arth.2017.06.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。