文献速递关节外科

骨水泥型单髁膝关节置换术后股骨与胫骨区域性放射透亮线及其与功能结果的关系

Regional Femoral and Tibial Radiolucency in Cemented Unicompartmental Knee Arthroplasty and the Relationship to Functional Outcomes.
PubMed 文献 · J Arthroplasty · 2017-06-19

这项回顾性研究纳入352例接受机器人辅助内侧骨水泥型固定平台金属托单髁膝关节置换术的患者,评估股骨和胫骨生理性放射透亮线及其与短期功能结果的关系。28.8%的患者出现生理性区域性放射透亮线,胫骨放射透亮线比股骨更常见(P < .001),股骨放射透亮线出现时间(1.36年)晚于胫骨(1.00年,P = .02),放射透亮线组与匹配对照组短期功能结果无差异。

要点

  • 352例骨水泥型内侧单髁膝关节置换术后28.8%出现生理性区域性放射透亮线。
  • 胫骨放射透亮线(25.3%)比股骨(10.3%)更常见(P < .001)。
  • 股骨放射透亮线出现时间1.36年,晚于胫骨1.00年(P = .02)。

核心结论

  • 骨水泥型内侧单髁膝关节置换术后可发生胫骨和股骨生理性放射透亮线。
  • 本研究首次显示生理性股骨放射透亮线出现时间晚于胫骨放射透亮线。
  • 放射透亮线组与无放射透亮线匹配队列组短期功能结果无差异。
  • 作者认为需要前瞻性研究、更长随访和更大样本量来比较不同单髁膝关节置换设计的放射透亮线及其与结果的关系。

研究设计与样本

  • 回顾性研究,纳入352例接受机器人辅助内侧单髁膝关节置换术并接受固定平台金属托骨水泥型内侧单髁膝关节置换的患者。
  • 影像学随访包括标准正位和侧位X线片。
  • 采用西安大略和麦克马斯特大学骨关节炎指数问卷评估功能结果,将放射透亮线患者按性别、年龄和体重指数与匹配队列比较。

主要发现

  • 101例患者(28.8%)出现股骨(10.3%)和/或胫骨(25.3%)假体周围生理性区域性放射透亮线,其中6.8%累及两个部件。
  • 胫骨放射透亮线比股骨放射透亮线更常见(P < .001)。
  • 数据提示股骨放射透亮线出现时间(1.36年)晚于胫骨放射透亮线(1.00年,P = .02)。
  • 放射透亮线组与无放射透亮线匹配队列组短期功能结果无差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者指出需要前瞻性研究、更长随访和更大样本量来比较不同单髁膝关节置换设计的放射透亮线及其与结果的关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Femoral and tibial radiolucent lines (RLL) after unicompartmental knee arthroplasty (UKA) can be categorized in physiological and pathological radiolucencies. Although physiological tibial radiolucency is assessed extensively in literature, studies reporting femoral radiolucency are lacking. Therefore, a retrospective study was performed to assess physiological femoral RLL and its relationship to short-term functional outcomes. METHODS: A total of 352 patients were included who underwent robotic-assisted medial UKA surgery and received a fixed-bearing metal-backed cemented medial UKA. Radiographic follow-up consisted of standard anteroposterior and lateral radiographs. Functional outcomes, using the Western Ontario and McMaster Universities Arthritis Index questionnaire, of patients with RLL were compared with a matched cohort, based on gender, age, and body mass index. RESULTS: In this cohort, 101 patients (28.8%) had physiological regional radiolucency around the femoral (10.3%) and/or tibial (25.3%) components, of which 6.8% concerned both components. Tibial RLL were more frequently seen compared with femoral RLL (P < .001). Our data suggest that the time of onset of femoral radiolucency develops later (1.36 years) than tibial radiolucency (1.00 years, P = .02). No difference in short-term functional outcomes was found between the RLL group and the matched cohort group without radiolucency. CONCLUSION: This study acknowledges that tibial and femoral physiological radiolucencies may develop after cemented medial UKA. Furthermore, this was the first study showing that physiological femoral RLL occur later than tibial RLL. Prospective studies with longer follow-up and larger numbers are necessary to compare radiolucency in different UKA designs and the relationship to outcomes.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kleeblad LJ, van der List JP, Zuiderbaan HA, et al. Regional Femoral and Tibial Radiolucency in Cemented Unicompartmental Knee Arthroplasty and the Relationship to Functional Outcomes. J Arthroplasty. 2017. PMID: 28697861. doi:10.1016/j.arth.2017.06.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。