文献速递关节外科

使用Kerboull髋臼加强装置与结构性同种异体骨移植翻修全髋关节置换术治疗严重髋臼缺损

Revision Total Hip Arthroplasty Using the Kerboull Acetabular Reinforcement Device and Structural Allograft for Severe Defects of the Acetabulum.
PubMed 文献 · J Arthroplasty · 2017-06-23

本研究回顾了65髋(59例患者)Paprosky 3A或3B型髋臼骨缺损翻修全髋关节置换术中使用Kerboull加强装置联合大块同种异体骨移植的经验,平均随访11.2年。Merle d'Aubigne髋关节评分从术前10.6分改善至末次随访17.1分(P < .05),15.2年以任何原因再翻修为终点的生存率为85.1%(95%CI 71-99)。作者结论认为尽管存在巨大骨缺损,该技术仍获得良好结果。

要点

  • Paprosky 3A/3B髋臼缺损翻修THA中,Kerboull装置联合大块植骨术后Merle d'Aubigne评分从10.6分改善至17.1分(P < .05)。
  • 术后影像显示植骨平均覆盖水平面负重区83.0%(34.6-100),所有病例植骨于12个月内完成融合。
  • 15.2年以任何原因再翻修为终点的生存率为85.1%(95%CI 71-99),出现4例影像学失败。

核心结论

  • 尽管存在巨大骨缺损,使用大块同种异体骨移植与Kerboull加强装置翻修全髋关节置换术获得了良好结果。

研究设计与样本

  • 回顾性研究,纳入65髋(59例患者,10例男性、49例女性)Paprosky 3A或3B型髋臼骨缺损行翻修全髋关节置换术,平均年龄59.1岁(23-85),平均随访11.2年(2-15)。

主要发现

  • Merle d'Aubigne髋关节评分从术前10.6分(5-15)改善至末次随访17.1分(15-18)(P < .05)。
  • 术后即刻影像显示植骨平均覆盖水平面负重区的83.0%(34.6-100),所有病例植骨于12个月内完成融合。
  • 4例出现影像学失败,原因为髋臼无菌性松动,平均发生于指数手术后10.8年(8-13),均显示大量骨丢失且圆形钢板任何部分均无法放置于宿主骨。
  • Kaplan-Meier分析显示,以任何原因再翻修手术为终点的15.2年生存率为85.1%(95%置信区间71-99)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of this study is to review our experience with Kerboull reinforcement device combined with bulk allograft for management of severe acetabular defects. METHODS: We investigated the results of revision total hip arthroplasty (THA) in 65 hips of 59 patients (10 male, 49 female) with Paprosky type 3A or 3B acetabular bone defects. Functional outcome was assessed using the Merle d'Aubigne hip score. Post-operative radiographs were examined for evidence of cup loosening. The mean age at revision THA was 59.1 years (23-85) and mean follow-up duration was 11.2 years (2-15). RESULTS: The Merle d'Aubigne hip score improved from 10.6 points (5-15) before surgery to 17.1 points (15-18) (P < .05) at the time of last investigation. In this series, mean coverage of the bone graft was 83.0% (34.6-100) of the loading portion in the horizontal plane on radiography immediately after revision. However, consolidation of the bone graft was completed within 12 months for all cases. There were 4 radiological failures due to acetabular aseptic loosening at a mean of 10.8 years (8-13) after index surgery; all 4 cases demonstrated massive bone loss that no part of the rounded plate could be placed on the host bone. Kaplan-Meier analysis showed that the 15.2-year survival rate was 85.1% (95% confidence interval 71-99) with re-revision surgery for any reason as the end point. CONCLUSION: Despite massive bone defects, we achieved favorable results for revision THA using bulk allograft and the Kerboull reinforcement device.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Makita H, Kerboull M, Inaba Y, et al. Revision Total Hip Arthroplasty Using the Kerboull Acetabular Reinforcement Device and Structural Allograft for Severe Defects of the Acetabulum. J Arthroplasty. 2017. PMID: 28711340. doi:10.1016/j.arth.2017.06.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。