髌股关节置换术矫正髌股关节对线不良
前瞻性研究16例接受髌股关节置换术患者,术前及术后6个月影像学测量髌骨倾斜角、髌骨高度及胫骨结节-滑车间距。术后髌骨倾斜角、Caton-Deschamps指数及TT-TG距离均改善,作者认为髌股关节置换术可矫正滑车发育不良并改善髌股关节一致性。
要点
- 髌股关节置换术可改善髌骨倾斜角及TT-TG距离。
- 术后Caton-Deschamps指数中位数由0.91升至1.11。
- 外侧髌骨面切除术与髌股关节置换术联合可减少髌骨倾斜。
核心结论
- 髌股关节置换术除替换关节炎软骨外,通过滑车截骨矫正滑车发育不良,改善髌股关节一致性并使髌骨倾斜角和TT-TG等放射学测量标准化。
- 联合外侧髌骨面切除术通过减少髌骨倾斜改善髌骨轨迹。
研究设计与样本
- 前瞻性研究系列,纳入16例接受髌股关节置换术的患者(13例女性,3例男性),年龄64.9±16.3岁(范围41-86岁)。
- 所有膝关节术前及术后6个月行正位、侧位及天际线位X线片和计算机断层扫描,计算髌骨倾斜角、髌骨高度及胫骨结节-滑车间距(TT-TG)。
主要发现
- 观察者间一致性对所有参数均极佳(组内相关系数>0.95)。
- 术前无股四头肌收缩时髌骨倾斜角中位数为17.5°(范围5.3°-33.4°),有股四头肌收缩时为19.8°(范围0°-52.0°)。
- 术前Caton-Deschamps指数中位数为0.91(范围0.80-1.22),TT-TG距离中位数为14.5 mm(范围4.0-22.0 mm)。
- 术后无股四头肌收缩时髌骨倾斜角中位数为0.3°(范围-15.3°至9.5°),有股四头肌收缩时为6.1°(范围-11.5°至13.3°)。
- 术后Caton-Deschamps指数中位数为1.11(范围0.81-1.20),TT-TG距离中位数为10.1 mm(范围1.8-13.8 mm)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The goal of patellofemoral arthroplasty (PFA) is to replace damaged cartilage and correct underlying deformities to reduce pain and prevent maltracking. We aimed to determine how PFA modifies patellar height, tilt, and tibial tuberosity-trochlear groove (TT-TG) distance. The hypothesis was that PFA would correct trochlear dysplasia or extensor mechanism malalignment. METHODS: The authors prospectively studied a series of 16 patients (13 women and 3 men) aged 64.9 ± 16.3 years (range 41-86 years) who received PFA. All knees were assessed preoperatively and 6 months postoperatively using frontal, lateral, and "skyline" x-rays, and computed tomography scans to calculate patellar tilt, patellar height, and TT-TG distance. RESULTS: The interobserver agreement was excellent for all parameters (intraclass correlation coefficient >0.95). Preoperatively, the median patellar tilt without quadriceps contraction (QC) was 17.5° (range 5.3°-33.4°) and with QC was 19.8° (range 0°-52.0°). The median Caton-Deschamps index was 0.91 (range 0.80-1.22) and TT-TG distance was 14.5 mm (range 4.0-22.0 mm). Postoperatively, the median patellar tilt without QC was 0.3° (range -15.3° to 9.5°) and with QC was 6.1° (range -11.5° to 13.3°). The median Caton-Deschamps index was 1.11 (range 0.81-1.20) and TT-TG distance was 10.1 mm (range 1.8-13.8 mm). CONCLUSION: The present study demonstrates that beyond replacing arthritic cartilage, trochlear-cutting PFA improves patellofemoral congruence by correcting trochlear dysplasia and standardizing radiological measurements as patellar tilt and TT-TG. The association of lateral patellar facetectomy improves patellar tracking by reducing the patellar tilt.
引用
- Valoroso M, Saffarini M, La Barbera G, et al. Correction of Patellofemoral Malalignment With Patellofemoral Arthroplasty. J Arthroplasty. 2017. PMID: 28735802. doi:10.1016/j.arth.2017.06.048
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。