骨盆倾斜与股骨头尺寸对髋关节撞击前活动范围的影响
研究使用髋关节模拟器导入10名受试者模型,测试不同骨盆倾斜角度及32毫米、36毫米股骨头与42毫米双动杯对撞击前活动范围的影响。结果显示头尺寸越大无撞击活动范围越大,骨盆后倾10°时无撞击区最大,前倾10°时无撞击杯前倾与外展组合更少,骨盆倾斜变化对拾物动作影响最大。
要点
- 股骨头尺寸越大,撞击前活动范围越大。
- 骨盆后倾10°时无撞击区最大,前倾10°时无撞击杯前倾与外展组合更少。
- 骨盆倾斜变化对拾物动作影响最大,可能需更个体化规划。
核心结论
- 考虑不同骨盆倾斜和股骨头尺寸时,无撞击活动范围的目标可能更小,尤其对拾物等特定动作。
- 这些发现可能提示需要更个体化的患者规划。
研究设计与样本
- 使用髋关节模拟器导入10名受试者模型,受试者执行拾物、下蹲和低椅起立动作。
- 设置骨盆倾斜、股骨柄前倾及受试者定义的特定运动参数,测定股骨与骨盆相对运动。
- 测试不同倾斜角度,以及32毫米和36毫米股骨头配标准杯和42毫米双动杯,选择外展与前倾组合并计算最小间隙或撞击。
主要发现
- 撞击前活动范围随不同骨盆倾斜、股骨头尺寸和不同运动而变化。
- 股骨头尺寸越大,无撞击活动范围越大。
- 骨盆后倾10°导致最大的无撞击区,而前倾10°与更少的无撞击杯前倾和外展角度组合相关。
- 骨盆倾斜变化对拾物动作影响最大,并影响无撞击「安全区」。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: About 50%-70% of dislocators have cups placed within so-called "safe zones." It has been postulated that factors such as femoral head size and pelvic tilt, obliquity, or rotation may influence postoperative stability. Therefore, we assessed varying degrees of pelvic tilt and head sizes on the range of motion (ROM) to impingement. METHODS: A hip simulator was used to import models of 10 subjects who performed object pickup, squatting, and low-chair rising. Parameters were set for pelvic tilt, stem version, and the specific motions as defined by the subjects. Femur-to-pelvis relative motions were determined for abduction/adduction, internal/external rotation, and flexion/extension. Varying tilt angles were tested. Thirty-two millimeter and 36-mm head with a standard cup and 42-mm dual mobility cup were tested. Cup orientations for abduction and anteversion combinations were chosen, and computations of minimum clearances or impingement between components were made. RESULTS: The ROM to impingement varied with the different pelvic tilts and femoral head sizes and with the different motions. The larger the head size, the larger the impingement-free ROM. Negative 10° of pelvic tilt led to the largest impingement-free zone, whereas 10° of forward tilt was associated with fewer impingement-free cup anteversion and abduction angle combinations. Variations in pelvic tilt had the greatest influence on object pickup and affected the impingement-free "safe zone." CONCLUSION: Targets for impingement-free motion may be smaller when considering varying pelvic tilts and femoral head sizes, particularly for certain activities, such as object pickup. These findings may indicate the need for more individualized patient planning.
引用
- McCarthy TF, Nevelos J, Elmallah RK, et al. The Effect of Pelvic Tilt and Femoral Head Size on Hip Range-of-Motion to Impingement. J Arthroplasty. 2017. PMID: 28712801. doi:10.1016/j.arth.2017.06.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。