股骨假体外旋增加后髁不对称性
研究分析110例骨关节炎膝关节术前CT,测量后髁在中立位及外旋3°和5°时的尺寸,发现外旋可放大内外侧髁不对称,中央参考系统较内侧参考系统产生更少潜在假体悬突。
要点
- 中立位时后髁尺寸近乎相等。
- 外旋3°和5°时,中央参考系统导致宽度不对称>3 mm者分别23膝(21%)和33膝(30%)。
- 内侧参考系统导致宽度不对称>3 mm者分别43膝(39%)和75膝(68%)。
核心结论
- 外旋可能放大内外侧髁之间的不对称,并加剧假体悬突,尤其在髁上外侧区域。
- 中央参考系统导板比内侧参考系统导板产生更少的潜在假体悬突。
研究设计与样本
- 研究分析了110例关节炎膝关节在初次全膝关节置换术时的术前CT扫描。
- 在中立位以及外旋3°和5°时,使用中央参考系统和内侧参考系统测量每个髁在股骨后髁截骨处的高度和宽度。
- 将形态学特征与14种全膝关节置换假体模型进行比较。
主要发现
- 中立位时,髁的尺寸近乎相等。
- 中央参考系统外旋3°时,23膝(21%)出现宽度不对称>3 mm;外旋5°时,33膝(30%)出现宽度不对称>3 mm。
- 内侧参考系统外旋3°时,43膝(39%)出现宽度不对称>3 mm;外旋5°时,75膝(68%)出现宽度不对称>3 mm。
- 旋转导致的不对称与性别、病因或内翻-外翻对线无关。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The morphometry of the distal femur was largely studied to improve bone-implant fit in total knee arthroplasty (TKA), but little is known about the asymmetry of the posterior condyles. This study aimed to investigate the dimensions of the posterior condyles and the influence of externally rotating the femoral component on potential prosthetic overhang or under-coverage. PATIENTS AND METHODS: We analysed the shape of 110 arthritic knees at the time of primary TKA using pre-operative CT scans. The height and width of each condyle were measured at the posterior femoral cut in neutral position, and in 3º and 5º of external rotation, using both central and medial referencing systems. We compared the morphological characteristics with those of 14 TKA models. RESULTS: In the neutral position, the dimensions of the condyles were nearly equal. Externally rotating the femoral cut by 3º and 5º with 'central referencing' induced width asymmetry > 3 mm in 23 (21%) and 33 (30%) knees respectively, while with 'medial referencing' it induced width asymmetry > 3 mm in 43 (39%) and 75 (68%) knees respectively. The asymmetries induced by rotations were not associated with gender, aetiology or varus-valgus alignment. CONCLUSION: External rotation may amplify the asymmetry between the medial and lateral condyles, and exacerbate prosthetic overhang, particularly in the superolateral zone. 'Central referencing' guides result in less potential prosthetic overhang than 'medial referencing' guides. Cite this article: Bone Joint J 2017;99-B:894-903.
引用
- Bonnin MP, Saffarini M, Nover L, et al. External rotation of the femoral component increases asymmetry of the posterior condyles. Bone Joint J. 2017. PMID: 28663394. doi:10.1302/0301-620X.99B7.BJJ-2016-0717.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。