文献速递关节外科

使用无骨水泥杯支撑器与髂骨自体骨移植的翻修全髋关节置换术:至少15年随访

Revision Total Hip Arthroplasty Using a Cementless Cup Supporter and Iliac Autograft: A Minimum of 15-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2017-06-20

本研究对59例(57例患者)采用村田-千叶杯支撑器(MC支撑环)联合髂骨自体骨移植重建髋臼骨缺损的翻修全髋关节置换术进行至少15年随访。平均随访17.6年,Harris髋关节评分从44.3改善至77.2,所有病例均实现骨移植整合,无因无菌性松动翻修髋臼杯,15年生存率(以再翻修或影像学失败为终点)为90.6%(95%CI 83.0%-98.8%)。结论认为该技术可获得满意的临床和影像学结果。

要点

  • 59例翻修全髋中,9髋为AAOS II型缺损,24髋为III型缺损,采用MC支撑环联合髂骨自体骨移植。
  • 平均随访17.6年,Harris髋关节评分从44.3改善至77.2。
  • 无因无菌性松动翻修髋臼杯,所有病例骨移植均整合,15年生存率90.6%(95%CI 83.0%-98.8%)。

核心结论

  • 使用MC支撑环支撑的自体骨移植重建髋臼骨缺损,在术后17.6年时提供了满意的临床和放射学结果。

研究设计与样本

  • 连续59例翻修全髋关节置换术(57例患者)使用MC支撑环,随访至少15年;9髋为美国骨科医师学会(AAOS)II型缺损,24髋为III型髋臼缺损。
  • 临床结果采用Harris髋关节评分评估,影像学评估包括松动和骨移植整合,并进行了Kaplan-Meier生存分析。

主要发现

  • 至少15年随访(平均17.6年)时,32例患者(33髋)存活,17例患者(18髋)死亡,8例患者(8髋)失访。
  • 平均Harris髋关节评分从44.3改善至末次随访时的77.2。
  • 4髋因深部感染(2髋)和内衬分离(2髋)需再手术,但无髋臼组件因无菌性松动而翻修。
  • 所有病例均发生骨移植整合;1例未翻修患者出现影像学失败。
  • 以再翻修或影像学失败为终点的15年生存率为90.6%(95%置信区间,83.0%-98.8%)。

关键数值与推荐

  • 骨缺损分型:9髋为AAOS II型,24髋为AAOS III型。
  • Harris髋关节评分从44.3改善至77.2。
  • 15年生存率90.6%(95%CI 83.0%-98.8%)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Bone deficiency in revision total hip arthroplasty is a surgical challenge. The Murata-Chiba cup supporter (MC support ring) is an acetabular component supporter for a cementless porous-coated cup. The purpose of this study is to examine the clinical and radiographic outcomes of reconstruction of acetabular bone deficiency using iliac autografts supported by an MC support ring in a revision setting with minimum 15-year follow-up. METHODS: Fifty-nine consecutive revision total hip arthroplasties (57 patients) using the MC support ring were followed for a minimum of 15 years. Nine hips had American Academy of Orthopaedic Surgeons type II deficiency and 24 had type III defects of the acetabulum. Clinical outcomes were evaluated using the Harris hip score. Radiographic evaluation included assessment for loosening and bone graft incorporation. Kaplan-Meier survival analysis was performed. RESULTS: At a minimum 15-year follow-up (mean, 17.6 years), 32 patients (33 hips) were alive, 17 patients (18 hips) were deceased, and 8 patients (8 hips) were lost to follow-up. The mean Harris hip score improved from 44.3 to 77.2 at final follow-up. Four hips required reoperation due to deep infection (2 hips) and liner dissociation (2 hips), but no acetabular components were revised for aseptic loosening. Incorporation of the bone graft occurred in all cases. One unrevised patient had radiographic failure. Survivorship at 15 years with re-revision or radiographic failure as the end point was 90.6% (95% confidence interval, 83.0%-98.8%). CONCLUSION: The reconstruction of acetabular bone deficiency using autografts supported by an MC support ring provided satisfactory clinical and radiological results at 17.6 years postoperatively.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Yoshino K, Tsukeoka T, Tsuneizumi Y, et al. Revision Total Hip Arthroplasty Using a Cementless Cup Supporter and Iliac Autograft: A Minimum of 15-Year Follow-Up. J Arthroplasty. 2017. PMID: 28697865. doi:10.1016/j.arth.2017.06.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。