回顾性分析42例Lenke 1型青少年特发性脊柱侧凸(AIS)后路椎弓根螺钉内固定病例,钛、钴铬、不锈钢棒各14例,比较术前、术后1周及2年随访的三维形态。结果显示主胸弯矫正平均75%(15°±6°,P<0.01),术后2年无变化(17°±7°,P=0.14);顶椎旋转矫正44%(13°±9°,P<0.01),术后2年无变化(14°±9°,P=0.64);各棒材料亚组三维矫正均维持(均P>0.05);腰椎前凸从术后1周47°±8°变为术后2年56°±9°(P<0.01);术后即刻矢状面姿态不平衡的患者2年后恢复平衡。
要点
- 主胸弯矫正平均75%(15°±6°,P<0.01),术后2年无变化(17°±7°,P=0.14)。
- 顶椎旋转矫正44%(13°±9°,P<0.01),术后2年无变化(14°±9°,P=0.64)。
- 钛、钴铬、不锈钢棒亚组三维矫正均维持(均P>0.05),腰椎前凸从术后1周47°±8°增至术后2年56°±9°(P<0.01)。
核心结论
- 对于钛、不锈钢和钴铬棒节段性椎弓根螺钉构造,内固定胸椎或棒在术后均无显著三维形态变化。
- 术后即刻记录为矢状面姿态不平衡的患者在术后2年恢复平衡。
研究设计与样本
- 回顾性分析42例接受后路椎弓根螺钉和5.5 mm棒内固定的Lenke 1型青少年特发性脊柱侧凸(AIS)病例,三种棒材料亚组各14例:钛、钴铬、不锈钢。
- 利用双平面X线片在术前、术后1周(1WPO)和2年随访(2YFU)进行脊柱三维重建,并在1WPO和2YFU重建棒的三维形态。
- 证据等级为3级。
主要发现
- 平均每椎体使用1.93枚植入物。
- 主胸弯(61°±9°)平均矫正75%(15°±6°,P<0.01),2YFU时无变化(17°±7°,P=0.14)。
- 顶椎旋转(23°±7°)矫正44%(13°±9°,P<0.01),2YFU时无变化(14°±9°,P=0.64)。
- 胸椎后凸(24°±12°)保持不变(P=0.78);主胸弯(39°±15°)和棒(凹侧:28°±23°,凸侧:12°±10°)最大弯曲平面相对于矢状面的方向在1WPO至2YFU无变化(均P>0.05);棒曲率和偏转也保持不变(均P>0.05)。
- 所有棒材料亚组三维弯曲矫正均在2YFU维持(均P>0.05);腰椎前凸从1WPO(47°±8°)变为2YFU(56°±9°,P<0.01);术前57%病例姿态平衡(骶骨垂直轴/骶股距离≤0.5且骶骨垂直轴≤0),1WPO为33%,2YFU为79%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Retrospective analysis of spine and rods 3D shape in the 2 years after adolescent idiopathic scoliosis (AIS) posterior surgical instrumentation. OBJECTIVE: To evaluate spine and rod shape 3D changes in the 2 years after AIS instrumentation with different rod materials. SUMMARY OF BACKGROUND DATA: Postoperative loss of correction has been reported with modern segmental instrumentation. The postoperative 3D rod shape changes of different rod materials and their implication in postoperative loss of correction have never been studied. METHODS: A total of 42 Lenke 1 AIS cases who underwent surgery all with pedicle screws and 5.5 mm rods of three different materials were retrospectively reviewed (14 cases for each of the three rod material subgroups: titanium, cobalt-chromium, stainless steel). 3D reconstructions of the spine were performed using biplanar radiographs preoperatively, 1-week postoperatively (1WPO), and 2 years follow-up (2YFU). Rods 3D shape also was reconstructed at 1WPO and 2YFU. The spine and rods shapes were analyzed and compared between time points. RESULTS: An average of 1.93 implant per vertebra was used. The main thoracic curve (61° ± 9°) was corrected on average by 75% (15° ± 6°, P < 0.01) with no change at 2YFU (17° ± 7°, P = 0.14). The apical vertebral rotation (23° ± 7°) was corrected by 44% (13° ± 9°, P < 0.01) with no change at 2YFU (14° ± 9°, P = 0.64). The thoracic kyphosis (24° ± 12°) remained unchanged (P = 0.78). The orientation of the planes of maximal curvature with respect to the sagittal plane of the main thoracic curve (39° ± 15°) and of the rods (concave: 28° ± 23°, convex: 12° ± 10°) at 1WPO was unchanged at 2YFU (all P > 0.05). Rod curvature and deflection also remained unchanged (all P > 0.05). 3D curve correction was maintained in the 2YFU for all rod materials subgroups (all P > 0.05). The lumbar lordosis changed from 1WPO (47° ± 8°) to 2YFU (56° ± 9°, P < 0.01). At preoperatively, 57% of the cases had a balanced posture (sacral vertical axis/sacral femoral distance ≤0.5 and sacral vertical axis ≤0), 33% at 1WPO and 79% at 2YFU. CONCLUSION: There was no significant 3D shape change of the instrumented thoracic spine or of the rods postoperatively for any of the segmental pedicle screw constructs with titanium, stainless steel, and cobalt-chromium rods. Patients overall unbalanced sagittal posture documented immediately after surgery came back to balanced 2 years after surgery. LEVEL OF EVIDENCE: 3.
引用
- Le Navéaux F, Labelle H, Parent S, et al. Are There 3D Changes in Spine and Rod Shape in the 2 Years After Adolescent Idiopathic Scoliosis Instrumentation? Spine (Phila Pa 1976). 2017. PMID: 28746140. doi:10.1097/BRS.0000000000002056
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。