文献速递脊柱外科小儿骨科

早发性脊柱侧弯患者的脊柱与胸廓高度测量具有优异的评估者间与评估者内信度

Spine and Thoracic Height Measurements Have Excellent Interrater and Intrarater Reliability in Patients With Early Onset Scoliosis.
PubMed 文献 · Spine (Phila Pa 1976) · 2018-01-01

本研究评估早发性脊柱侧弯(EOS)患者脊柱与胸廓高度放射学测量的信度与测量标准误,由两名小儿脊柱外科主治医师、两名小儿骨科 fellow 和两名研究助理在至少间隔3周的两个时间点测量48例患者的T1-S1与T1-T12高度。结果显示脊柱高度评估者间ICC为0.894(95%CI 0.847-0.932)、胸廓高度为0.890(95%CI 0.844-0.929),评估者内ICC分别为0.906(95%CI 0.830-0.943)和0.898(95%CI 0.817-0.938),均属优异。

要点

  • EOS患者脊柱高度(T1-S1)评估者间ICC为0.894(95%CI 0.847-0.932),胸廓高度(T1-T12)为0.890(95%CI 0.844-0.929)。
  • 脊柱高度评估者内ICC为0.906(95%CI 0.830-0.943),胸廓高度为0.898(95%CI 0.817-0.938)。
  • 样本按C-EOS诊断分层随机抽样,共纳入48例EOS患者。

核心结论

  • 在本机构EOS人群中,脊柱与胸廓高度的放射学测量具有优异的评估者间与评估者内信度。

研究设计与样本

  • 测量可重复性研究,采用按C-EOS诊断分层随机抽样策略,最终纳入48例EOS患者。
  • 基于预试验数据确定测量49张独立X线片可使评估者间ICC的95%CI宽度达到0.05时具有80%把握度。
  • 由两名小儿脊柱外科主治医师、两名小儿骨科fellow和两名研究助理使用Surgimap软件在至少间隔3周的两个时间点测量T1-S1与T1-T12高度,第二次测量顺序随机化。
  • 采用线性混合模型回归分析估计评估者间与评估者内信度。

主要发现

  • 样本包括特发性17例(35%)、先天性16例(33%,1例被排除)、神经肌肉性11例(23%)和综合征性4例(8%)脊柱侧弯。
  • 脊柱高度评估者间ICC为0.894(95%CI 0.847-0.932),胸廓高度为0.890(95%CI 0.844-0.929),均属优异。
  • 脊柱高度评估者内ICC为0.906(95%CI 0.830-0.943),胸廓高度为0.898(95%CI 0.817-0.938),均属优异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Reproducibility of measurements. OBJECTIVE: This study investigates the reliability and standard error of measurement of spine and thoracic height radiographic measurements in patients with early onset scoliosis (EOS). SUMMARY OF BACKGROUND DATA: Spine and thoracic height radiographic measurements are often used as a surrogate for pulmonary development in patients with EOS. There is limited literature validating the reliability of spine and thoracic height measurements in the EOS population. METHODS: Using pilot data, we determined measuring 49 unique radiographs would provide 80% power to obtain a 95% confidence interval (CI) width of 0.05 for the interclass correlation coefficients (ICCs). A random sampling strategy, stratified by underlying diagnosis from the Classification of Early Onset Scoliosis (C-EOS), was used to distribute the diagnoses in the study sample. Two attending pediatric spine surgeons, two pediatric orthopedic fellows, and two research assistants measured coronal spine (T1-S1) and thoracic (T1-T12) height on digital radiographs using imaging software (Surgimap; Nemaris, Inc, New York) on two separate occasions at least 3 weeks apart. Order of images was randomized for the second iteration. Linear mixed model regression analyses were used to estimate interrater and intrarater reliability. RESULTS: The study sample included subjects (N = 48) with idiopathic (N = 17, 35%), congenital (N = 16, 33%, 1 patient excluded), neuromuscular (N = 11, 23%), and syndromic (N = 4, 8%) scoliosis. Overall interrater reliability estimates for spine height (ICC: 0.894, 95% CI: 0.847-0.932) and thoracic height (ICC: 0.890, 95% CI: 0.844-0.929) were excellent. Intrarater reliability estimates for spine height (ICC: 0.906, 95% CI: 0.830-0.943) and thoracic height (ICC: 0.898, 95% CI: 0.817-0.938) were also excellent. CONCLUSION: There is excellent interrater and intrarater reliability for radiographic measurements of spine and thoracic height in the EOS population at our institution. LEVEL OF EVIDENCE: 2.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Michael N, Carry P, Erickson M, et al. Spine and Thoracic Height Measurements Have Excellent Interrater and Intrarater Reliability in Patients With Early Onset Scoliosis. Spine (Phila Pa 1976). 2018. PMID: 28665821. doi:10.1097/BRS.0000000000002314

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。