第二代锥形楔形股骨柄降低术中股骨骨折发生率
这项单中心回顾性研究分析了2006至2016年6473例初次全髋关节置换术,比较第一代与第二代非骨水泥锥形楔形股骨柄。第一代柄术中骨折发生率为1.79%,第二代为0.24%,风险降低7.5倍;校正协变量后第二代柄术中骨折的比值比为0.33(P = .01),但术后30天早期假体周围骨折的比值比无显著差异(OR 0.93,P = .56)。
要点
- 第一代柄术中骨折发生率为1.79%,第二代柄为0.24%,风险降低7.5倍。
- 校正协变量后,第二代柄术中骨折的OR为0.33(P = .01)。
- 术后30天早期假体周围骨折的OR为0.93(P = .56),无显著差异。
核心结论
- 与上一代股骨柄相比,新型第二代非骨水泥股骨柄使术中股骨骨折发生率降低7.5倍。
研究设计与样本
- 单中心回顾性研究,纳入2006至2016年使用第一代或第二代非骨水泥股骨柄的初次全髋关节置换术病例。
- 共6473例初次全髋关节置换术使用非骨水泥锥形楔形股骨柄,其中第一代柄3126例,第二代柄3347例。
- 识别所有术中股骨骨折及术后30天早期假体周围股骨骨折,采用逻辑回归分析术中股骨骨折风险,并校正人口学协变量和外科医生。
主要发现
- 第一代柄术中骨折发生率为1.79%,第二代柄为0.24%,风险降低7.5倍。
- 校正协变量后,第二代柄相对于第一代柄的术中骨折比值比为0.33(P = .01)。
- 第二代柄术后30天早期骨折的比值比为0.93(P = .56),无显著差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Intraoperative fractures during total hip arthroplasty (THA) are more common when using cementless stems. The purpose of this study was to investigate the impact of a new shorter second-generation cementless, tapered wedge stem with improved proximal femoral fit in reducing the incidence of intraoperative fracture. METHODS: A retrospective study was conducted on primary THA cases performed at a single institution using a first-generation or second-generation cementless stem from 2006-2016. All intraoperative femur fractures were identified, as well as early 30-day postoperative periprosthetic femur fractures, which could represent nondisplaced intraoperative fractures that were initially missed. Risk for intraoperative femur fracture was analyzed using logistic regression, accounting for demographic covariates and surgeon. RESULTS: Of 6473 primary THA performed with a cementless, tapered wedge stem during the study period, 3126 used a first-generation stem and 3347 used a second-generation stem. The incidence of intraoperative fracture was 1.79% for first-generation stems and 0.24% for second-generation stems, representing a 7.5-fold reduction of risk for fracture. After accounting for covariates, the odds of intraoperative fracture were 0.33 using the second-generation stem relative to the first-generation stem (P = .01). However, there was no significant difference in the odds of early 30-day postoperative fractures using the second-generation stem (odds ratio 0.93, P = .56). CONCLUSION: A new second-generation cementless stem resulted in a 7.5-fold decrease in the incidence of intraoperative femur fracture compared with the preceding stem.
引用
- Fleischman AN, Schubert MM, Restrepo C, et al. Reduced Incidence of Intraoperative Femur Fracture With a Second-Generation Tapered Wedge Stem. J Arthroplasty. 2017. PMID: 28676374. doi:10.1016/j.arth.2017.06.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。