去端肽胶原促进兔模型肩袖肌腱愈合
研究在46只新西兰白兔中建立冈上肌腱撕裂并修复模型,随机分实验组(修复时骨与肌腱间植入补片型去端肽胶原)与对照组(单纯修复),每组23只(15只组织学、8只生物力学)。12周时实验组组织学评分4.0±1.0显著优于对照组7.7±2.7(P=.005),失败载荷实验组51.4±3.9 N显著高于对照组36.4±5.9 N(P=.001)。结论认为去端肽胶原在兔冈上肌腱撕裂模型中组织学与生物力学结果更好。
要点
- 12周组织学评分实验组4.0±1.0 vs 对照组7.7±2.7,实验组更优(P=.005)。
- 12周失败载荷实验组51.4±3.9 N vs 对照组36.4±5.9 N,实验组更高(P=.001)。
- 作者认为去端肽胶原补片可用于肩袖修复部位以促进愈合。
核心结论
- 在兔冈上肌腱撕裂模型中,使用去端肽胶原的实验组组织学与生物力学结果均优于对照组。
研究设计与样本
- Controlled laboratory study:46只新西兰白兔建立冈上肌腱撕裂并修复,随机分2组,每组23只(15只用于组织学、8只用于生物力学测试)。
- 实验组修复时在骨与肌腱之间植入补片型去端肽胶原,对照组不作去端肽胶原处理单纯修复,对侧肩作为假手术(仅暴露肌腱)。
- 组织学评估于4、8、12周进行,生物力学拉伸强度于术后12周测试。
主要发现
- 12周组织学评估评分实验组4.0±1.0 vs 对照组7.7±2.7,实验组显著更优(P=.005)。
- 12周失败载荷实验组51.4±3.9 N vs 对照组36.4±5.9 N,实验组显著更高(P=.001)。
临床怎么用
- 作者指出,去端肽胶原补片可用于肩袖修复部位以促进愈合。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Failure of rotator cuff healing is a common complication despite the rapid development of surgical repair techniques for the torn rotator cuff. PURPOSE: To verify the effect of atelocollagen on tendon-to-bone healing in the rabbit supraspinatus tendon compared with conventional cuff repair. STUDY DESIGN: Controlled laboratory study. METHODS: A tear of the supraspinatus tendon was created and repaired in 46 New Zealand White rabbits. They were then randomly allocated into 2 groups (23 rabbits per group; 15 for histological and 8 for biomechanical test). In the experimental group, patch-type atelocollagen was implanted between bone and tendon during repair; in the control group, the torn tendon was repaired without atelocollagen. Each opposite shoulder served as a sham (tendon was exposed only). Histological evaluation was performed at 4, 8, and 12 weeks. Biomechanical tensile strength was tested 12 weeks after surgery. RESULTS: Histological evaluation scores of the experimental group (4.0 ± 1.0) were significantly superior to those of the control group (7.7 ± 2.7) at 12 weeks ( P = .005). The load to failure was significantly higher in the experimental group (51.4 ± 3.9 N) than in the control group (36.4 ± 5.9 N) ( P = .001). CONCLUSION: Histological and biomechanical studies demonstrated better results in the experimental group using atelocollagen in a rabbit model of the supraspinatus tendon tear. CLINICAL RELEVANCE: Atelocollagen patch could be used in the cuff repair site to enhance healing.
引用
- Suh DS, Lee JK, Yoo JC, et al. Atelocollagen Enhances the Healing of Rotator Cuff Tendon in Rabbit Model. Am J Sports Med. 2017. PMID: 28586622. doi:10.1177/0363546517703336
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。