某模块化股骨柄设计的植入物骨折率惊人地高:两种植入物的比较
回顾性单术者研究比较1168例全髋关节置换术中Emperion与S-ROM两种柄套模块化股骨柄的植入物失败率,Emperion组7例患者发生8例(1.5%)骨折,S-ROM组发生1例(0.2%)骨折(P = .015),作者推荐更审慎地使用模块化。
要点
- Emperion组骨折8例(1.5%)vs S-ROM组1例(0.2%),P = .015,Emperion组骨折率更高。
- 共纳入1168例全髋关节置换术,Emperion组547例(47%),S-ROM组621例(53%)。
- 作者推荐更审慎地使用模块化,用于初次全髋关节置换术。
核心结论
- 研究中柄骨折的确切原因仍未知,可能是多因素的;鉴于柄套连接处柄骨折形式的灾难性植入物失败率出乎意料地高,作者推荐更审慎地使用模块化,用于初次全髋关节置换术。
研究设计与样本
- 回顾性、单术者、机构数据库回顾,比较两组患者。
主要发现
- 共纳入1168例全髋关节置换术,Emperion组547例(47%),S-ROM组621例(53%)。
- Emperion组7例患者发生8例(1.5%)骨折,S-ROM组发生1例(0.2%)骨折(P = .015)。
临床怎么用
- 作者推荐更审慎地使用模块化,用于初次全髋关节置换术。
局限性
- 研究中柄骨折的确切原因仍未知,可能是多因素的。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Reports of implant fracture at the modular junction have been seen in modular neck designs, stem-sleeve modular femoral stems, and diaphyseal engaging bi-body modular stems. To date, however, there has never been a direct comparison between 2 different implant designs from the same modular family. The purpose of this study is to compare the rate of implant failure of 2 such stem-sleeve modular femoral stem designs, the S-ROM and Emperion, to further identify factors which increase the risk of this mode of failure. METHODS: A retrospective, single surgeon, review of our institutional database was performed to compare the 2 groups of patients. RESULTS: A total of 1168 total hip arthroplasty procedures were included in our analysis, 547 (47%) with Emperion and 621 (53%) with S-ROM. Eight (1.5%) fractures in 7 patients occurred in the Emperion group compared to 1 (0.2%) fracture in the S-ROM group (P = .015). CONCLUSION: The precise cause of the stem fractures in our study remains unknown and is likely multifactorial. Given the unexpectedly high rate of catastrophic implant failures in the form of stem fracture at the stem-sleeve junction, we recommend more judicious use of modularity in primary total hip arthroplasty.
引用
- Shah RR, Goldstein JM, Cipparrone NE, et al. Alarmingly High Rate of Implant Fractures in One Modular Femoral Stem Design: A Comparison of Two Implants. J Arthroplasty. 2017. PMID: 28634092. doi:10.1016/j.arth.2017.05.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。