文献速递关节外科小儿骨科

单侧Crowe IV型发育性髋关节发育不良全髋关节置换联合股骨横行短缩截骨术后髋、膝、踝冠状面力线变化

Changes in Hip, Knee, and Ankle Coronal Alignments After Total Hip Arthroplasty With Transverse Femoral Shortening Osteotomy for Unilateral Crowe Type IV Developmental Dysplasia of the Hip.
PubMed 文献 · J Arthroplasty · 2017-06-01

回顾25例单侧Crowe IV型发育性髋关节发育不良行全髋关节置换联合股骨横行短缩截骨术患者的术前及术后1年下肢全长X线片,测量双侧股骨偏心距(FO)、机械髋-膝-踝角、机械轴偏移(MAD)等参数。术后手术侧FO(P=.001)、髋-膝-踝角(P=.004)、MAD(P=.016)、机械股骨近端外侧角(P=.001)、解剖股骨近端内侧角(P=.012)、机械股骨远端外侧角(P=.043)及踝关节线方向角(P=.012)均有显著变化;非手术侧仅MAD(P=.035)有显著变化。结论认为FO调整与髋关节解剖重建使膝、踝外翻力线趋于中立,对非手术侧影响极小。

要点

  • 术后手术侧FO、髋-膝-踝角、MAD、机械股骨近端外侧角、解剖股骨近端内侧角、机械股骨远端外侧角及踝关节线方向角均显著改变。
  • 术后非手术侧仅MAD显著改变(P=.035),其余参数无显著变化。
  • 作者认为FO调整与髋关节解剖重建使膝、踝外翻力线趋于中立,对非手术侧影响极小。

核心结论

  • 作者认为,FO调整与髋关节解剖重建使膝和踝外翻力线趋于中立,对非手术侧影响极小。

主要发现

  • 术后手术侧FO(P=.001)、髋-膝-踝角(P=.004)、MAD(P=.016)、机械股骨近端外侧角(P=.001)、解剖股骨近端内侧角(P=.012)、机械股骨远端外侧角(P=.043)及踝关节线方向角(P=.012)均有显著变化。
  • 术后非手术侧仅MAD(P=.035)有显著变化。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To investigate changes in lower extremity coronal alignment in patients with unilateral Crowe type IV developmental dysplasia of the hip who underwent total hip arthroplasty with transverse femoral shortening osteotomy. METHODS: We reviewed the preoperative and 1-year postoperative full-length lower extremity radiographs of 25 patients. Femoral offset (FO), mechanical hip-knee-ankle angle, anatomical axis, mechanical axis deviation (MAD), mechanical lateral proximal femoral angle, anatomical medial proximal femoral angle, mechanical lateral distal femoral angle, anatomical lateral distal femoral angle, knee joint line congruency angle, mechanical medial proximal tibial angle, mechanical lateral distal tibial angle, ankle joint line orientation angle, tibial plafond talus angle, extremity length, and pelvic obliquity were measured on both the operative and nonoperative sides. RESULTS: Postoperatively, there were significant changes in FO (P = .001), hip-knee-ankle angle (P = .004), MAD (P = .016), mechanical lateral proximal femoral angle (P = .001), anatomical medial proximal femoral angle (P = .012), mechanical lateral distal femoral angle (P = .043), and ankle joint line orientation angle (P = .012) on the operative side. Only MAD (P = .035) changed significantly on the nonoperative side. CONCLUSION: Modification of FO and reconstruction of hip joint anatomy led to neutralization of knee and ankle valgus alignment. Effects on the nonoperative side were minimal.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kocabiyik A, Misir A, Kizkapan TB, et al. Changes in Hip, Knee, and Ankle Coronal Alignments After Total Hip Arthroplasty With Transverse Femoral Shortening Osteotomy for Unilateral Crowe Type IV Developmental Dysplasia of the Hip. J Arthroplasty. 2017. PMID: 28641973. doi:10.1016/j.arth.2017.05.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。