文献速递关节外科

翻修全髋关节置换术中模块化与非模块化锥形带槽钛柄的差异

What Is the Difference Between Modular and Nonmodular Tapered Fluted Titanium Stems in Revision Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-05-18

回顾性比较160例模块化与129例非模块化锥形带槽钛柄翻修全髋关节置换术,模块化组术中骨折发生率显著更高(16.9% vs 7.0%,P=0.011),柄下沉显著更少(0.95 mm vs 1.93 mm,P=0.001),两组术后Harris髋关节评分、总体满意度、8年累积生存率及感染、脱位、假体周围骨折率无显著差异。

要点

  • 模块化组术中骨折发生率16.9%,显著高于非模块化组的7.0%(P=0.011)。
  • 模块化组柄下沉0.95 mm,显著少于非模块化组的1.93 mm(P=0.001)。
  • 两组术后Harris髋关节评分、总体满意度、8年累积生存率及感染、脱位、假体周围骨折率无显著差异。

核心结论

  • 模块化与非模块化锥形带槽钛柄在翻修全髋关节置换术中均提供满意的中期结果。
  • 尽管模块化锥形带槽柄在翻修全髋关节置换术中越来越受欢迎,非模块化锥形带槽柄不应被忽视,尤其对于相对简单的病例,其仍是可行的替代选择。

研究设计与样本

  • 回顾性综述纳入2002年至2014年间使用模块化锥形带槽钛柄翻修的160例连续全髋关节置换术(153例患者)。
  • 回顾性综述纳入2008年至2014年间使用非模块化锥形带槽钛柄翻修的129例连续全髋关节置换术(128例患者)。
  • 评估患者满意度水平、临床评估和并发症,并以因感染性/无菌性并发症导致的任何再手术为终点进行Kaplan-Meier生存分析。

主要发现

  • 模块化组平均随访时间6.3年,长于非模块化组的5.0年(P=0.003)。
  • 模块化组术中骨折发生率为16.9%,非模块化组为7.0%,模块化组显著更高(P=0.011)。
  • 模块化组柄下沉为0.95 mm,非模块化组为1.93 mm,模块化组显著更少(P=0.001)。
  • 两组术后Harris髋关节评分、总体满意度水平、8年累积生存率、感染率、脱位率或术后假体周围骨折率均无显著组间差异。
  • 模块化组发生2例与模块化设计相关的机械失败。

临床怎么用

  • 作者认为,尽管模块化锥形带槽柄在翻修全髋关节置换术中越来越受欢迎,非模块化锥形带槽柄不应被忽视,尤其对于相对简单的病例,其仍是可行的替代选择。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Both modular and nonmodular tapered fluted titanium stems are used in revision total hip arthroplasty (THA), with follow-up showing good results for both stems. We aimed to determine whether there were any differences in clinical outcomes, survivorship, or frequency of complications. METHODS: A retrospective review of 160 consecutive THAs (153 patients) revised with a tapered fluted modular titanium stem from 2002 to 2014 and 129 consecutive THAs (128 patients) revised with a tapered fluted nonmodular titanium stem between 2008 and 2014 was conducted. The patient's level of satisfaction, clinical assessment, and complications were examined. A Kaplan-Meier survivorship analysis was performed with the endpoint defined as any reoperation due to septic/aseptic complications. RESULTS: Mean duration of follow-up was longer in the modular group (6.3 years) than the nonmodular group (5.0 years; P = .003). No significant group differences were found in the postoperative Harris Hip Score, the level of overall satisfaction, the 8-year cumulative survival, the rate of infection, dislocation, or postoperative periprosthetic fractures. However, intraoperative fractures occurred significantly more frequently in the modular group (16.9%) than in the nonmodular group (7.0%; P = .011), and stem subsidence was significantly less in the modular group (0.95 mm) than in the nonmodular group (1.93 mm; P = .001). Two mechanical failures associated with the modular design occurred in the modular group. CONCLUSION: Both modular and nonmodular tapered fluted titanium stems provide satisfactory midterm results in revision THA. Although tapered fluted modular stems are gaining in popularity in revision THA, tapered fluted nonmodular stems should not be disregarded as a viable alternative, especially for relatively straightforward cases.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Huang Y, Zhou Y, Shao H, et al. What Is the Difference Between Modular and Nonmodular Tapered Fluted Titanium Stems in Revision Total Hip Arthroplasty. J Arthroplasty. 2017. PMID: 28602532. doi:10.1016/j.arth.2017.05.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。