文献速递关节外科

柄尺寸与固定方式对翻修全膝关节置换术后机械失败的影响

Effect of Stem Size and Fixation Method on Mechanical Failure After Revision Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-05-04

本研究回顾性分析了223例初次使用带柄组件的翻修全膝关节置换术患者,平均随访61.6个月,其中108个组件采用全骨水泥柄、316个组件采用「混合」压配柄。基于时间-事件模型,骨水泥柄与混合柄的机械失败风险相当(相对风险0.991,P=0.98)。年轻是机械失败唯一最大危险因素(P=0.006)。

要点

  • 骨水泥柄与混合压配柄的机械失败风险相当(相对风险0.991,P=0.98)。
  • 年轻是机械失败唯一最大危险因素(P=0.006)。
  • 混合柄中,髓腔填充率而非柄长度或直径是失败最强预测因素,每增加10%填充率风险降低41.2%。

核心结论

  • 骨水泥柄和混合模块柄均是翻修全膝关节置换术的可行选择。
  • 作者建议,外科医生应尽量最大化混合柄的髓腔填充以获得牢固压配。
  • 作者认为,需要进一步研究评估年轻患者骨水泥柄固定的长期生存率。

研究设计与样本

  • 回顾性综述,纳入223例既往未使用带柄组件、接受翻修全膝关节置换术的患者,平均随访61.6个月,包括108个全骨水泥柄组件和316个「混合」压配柄组件。

主要发现

  • 基于时间-事件模型,骨水泥柄与混合柄的机械失败风险相当(相对风险0.991,P=0.98)。
  • 年轻是机械失败唯一最大危险因素(P=0.006)。
  • 在年龄<65岁的患者中,骨水泥柄有失败增加的趋势,但校正协变量后风险无显著差异(相对风险1.4,P=0.50)。
  • 混合柄中,髓腔填充率而非柄长度或直径是失败最强预测因素,每增加10%填充率风险降低41.2%。

关键数值与推荐

  • 骨水泥柄 vs 混合柄机械失败相对风险0.991(P=0.98)。
  • 年龄<65岁患者中骨水泥柄 vs 混合柄校正后相对风险1.4(P=0.50)。
  • 混合柄每增加10%髓腔填充率,失败风险降低41.2%。

临床怎么用

  • 作者建议,外科医生应尽量最大化混合柄的髓腔填充以获得牢固压配。
  • 作者认为,需要进一步研究评估年轻患者骨水泥柄固定的长期生存率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although the need for stemmed components is well accepted to improve mechanical survival in revision total knee arthroplasty (TKA), the ideal fixation method and stem design remain controversial. METHODS: We performed a retrospective review of 223 patients who underwent revision TKA in whom stemmed components had not been used previously and with a mean follow-up of 61.6 months, including 108 components with fully cemented stems and 316 components with "hybrid" press-fit stems. RESULTS: Based on a time to event model, risk for mechanical failure was equivalent for both cemented and hybrid stems (relative risk, 0.991; P = .98). Young age was the single greatest risk factor for mechanical failure (P = .006). Although there was a trend toward increased failure with cemented stems in patients aged <65 years, there was no significant difference in risk after accounting for covariates (relative risk, 1.4; P = .50). Intramedullary canal fill, not stem length or diameter, was the strongest predictor of failure with hybrid stems, and risk was reduced by 41.2% for each additional 10% canal fill. CONCLUSION: In conclusion, both cemented and hybrid modular stems are viable options in revision TKA. Surgeons should attempt to maximize canal filling of hybrid stems to obtain a solid press-fit. In addition, further studies are needed to evaluate the long-term survival of cemented stem fixation in young patients.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Fleischman AN, Azboy I, Fuery M, et al. Effect of Stem Size and Fixation Method on Mechanical Failure After Revision Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28559193. doi:10.1016/j.arth.2017.04.055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。