100例膝关节后胫骨平台斜率的三维计算机断层扫描分析
本研究对100例无疾病膝关节的三维CT扫描进行分析,分别以胫骨平台和踝关节旋转对齐测量后胫骨平台斜率(PTS)。以胫骨平台对齐时平均PTS为11.2°±3.0,以踝关节对齐时平均PTS为11.4°±3.0。正常亚洲膝关节PTS平均约11°,参考范围为5°-17°。
要点
- 以胫骨平台旋转对齐时,平均PTS为11.2°±3.0,内侧PTS为11.3°±3.2,外侧PTS为10.9°±3.7。
- 以踝关节旋转对齐时,平均PTS为11.4°±3.0,内侧PTS为13.9°±3.7,外侧PTS为9.7°±3.6。
- 正常亚洲膝关节PTS平均约11°,参考范围为5°-17°(均值±2个标准差)。
核心结论
- 正常亚洲膝关节的PTS平均约11°,参考范围为5°-17°(均值±2个标准差),这对手术和植入物设计有影响。
研究设计与样本
- 研究分析了100例无疾病膝关节的计算机断层扫描,生成胫骨三维重建图像并在冠状面和矢状面与解剖轴对齐,分别以胫骨平台(胫骨质心轴)和踝关节(经踝轴)旋转对齐测量PTS。
主要发现
- 以胫骨平台旋转对齐时,平均PTS为11.2°±3.0(范围4.7°-17.7°),内侧PTS为11.3°±3.2(范围2.7°-19.7°),外侧PTS为10.9°±3.7(范围3.5°-19.4°)。
- 以踝关节旋转对齐时,平均PTS为11.4°±3.0(范围5.3°-19.3°),内侧PTS为13.9°±3.7(范围3.1°-24.4°),外侧PTS为9.7°±3.6(范围0.8°-17.7°)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The posterior tibial slope (PTS) is an important consideration in knee arthroplasty. However, there is still no consensus for the optimal slope. The objectives of this study were (1) to reliably determine the native PTS in this population using 3-dimensional computed tomography scans and (2) to determine the normal reference range for PTS in this population. METHODS: One hundred computed tomography scans of disease-free knees were analyzed. A 3-dimensional reconstructed image of the tibia was generated and aligned to its anatomic axis in the coronal and sagittal planes. The tibia was then rotationally aligned to the tibial plateau (tibial centroid axis) and PTS was measured from best-fit planes on the surface of the proximal tibia and individually for the medial and lateral plateaus. This was then repeated with the tibia rotationally aligned to the ankle (transmalleolar axis). RESULTS: When rotationally aligned to the tibial plateau, the mean PTS, medial PTS, and lateral PTS were 11.2° ± 3.0 (range, 4.7°-17.7°), 11.3° ± 3.2 (range, 2.7°-19.7°), and 10.9° ± 3.7 (range, 3.5°-19.4°), respectively. When rotationally aligned to the ankle, the mean PTS, medial PTS, and lateral PTS were 11.4° ± 3.0 (range, 5.3°-19.3°), 13.9° ± 3.7 (range, 3.1°-24.4°), and 9.7° ± 3.6 (range, 0.8°-17.7°), respectively. CONCLUSION: The PTS in the normal Asian knee is on average 11° (mean) with a reference range of 5°-17° (mean ± 2 standard deviation). This has implications to surgery and implant design.
引用
- Ho JPY, Merican AM, Hashim MS, et al. Three-Dimensional Computed Tomography Analysis of the Posterior Tibial Slope in 100 Knees. J Arthroplasty. 2017. PMID: 28579444. doi:10.1016/j.arth.2017.04.060
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。