召回的关节面置换髋假体所致血清钴水平升高对视觉通路的影响
本研究纳入33例关节面置换(ASR)髋假体患者与33名非ASR对照,比较血清钴水平及多项视觉心理物理与电生理检查,并以视觉电生理数据库人群数据作为第二对照。ASR组血清钴中位数显著高于对照1组,视网膜电图混合视杆-视锥b波振幅及视诱发电位潜伏期与对照组存在统计学差异,但未转化为可识别的临床视觉缺陷;作者不建议常规视觉检查。
要点
- ASR组血清钴中位数52 nmol/L,显著高于对照1组的7 nmol/L(P < .0001)。
- ASR组视网膜电图混合视杆-视锥b波振幅显著大于两个对照组(P = .0294和.0410)。
- ASR组视诱发电位潜伏期较对照2组显著延长(P = .0201),但视力无统计学差异。
核心结论
- ASR组与对照组相比存在有统计学意义的视觉电生理 disturbance,但这些差异未转化为可识别的临床视觉缺陷;作者认为骨科医生需意识到ASR及其他金属对金属髋关节置换患者可能存在视觉功能障碍,但不推荐常规视觉检查。
研究设计与样本
- 队列研究,纳入33例ASR患者和33名非ASR对照(对照1),并与视觉电生理数据库的正常人群数据(对照2)比较;排除2例已有眼病者后,对33例ASR患者数据与两个对照队列进行比较。
主要发现
- ASR组血清钴中位数52 nmol/L(四分位距14-151 nmol/L)显著高于对照1组中位数7 nmol/L(四分位距5-14 nmol/L),P < .0001。
- ASR组视网膜电图混合视杆-视锥b波振幅显著大于对照1组和对照2组,P分别为.0294和.0410。
- 多焦和暗适应视网膜电图反映的黄斑功能异常在对照1组更常见,P分别为.0445和.0275。
- ASR组视诱发电位潜伏期较对照2组显著延长,P = .0201。
- 视力检查无统计学差异。
临床怎么用
- 作者认为骨科医生需意识到ASR及其他金属对金属髋关节置换患者可能存在视觉功能障碍,但不推荐常规视觉检查。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The articular surface replacement (ASR) was recalled in 2010 because of higher than expected revision rates. Patients reported symptoms of neurologic dysfunction including poor vision. This cohort study, using objective measurements, aimed to establish whether a higher incidence of visual function defects exists in ASR patients. METHODS: Thirty-three ASR patients and 33 non-ASR controls (control 1) were recruited. Data were compared with normative population data from the visual electrophysiology database (control 2). Patients underwent investigations for serum cobalt levels, psychophysical visual tests, and extensive electrophysiological visual testing. RESULTS: After excluding 2 subjects with pre-existing eye disease, data from 33 ASR patients were compared with the 2 control cohorts. The median serum cobalt level in the ASR group (median, 52 nmol/L [interquartile range, 14-151 nmol/L]) was significantly higher than that in the control 1 cohort (median, 7 nmol/L [interquartile range, 5-14 nmol/L]; P < .0001). The photoreceptor function of patients with an ASR of the hip showed significantly larger electroretinography mixed rod-cone b-wave amplitudes than both control 1 and control 2 cohorts (P = .0294 and .0410, respectively). Abnormalities in macular function as reflected by multifocal and scotopic electroretinography were more prevalent in control 1 (P = .0445 and .0275, respectively). Optic nerve pathway measurements using visual-evoked potential latency was significantly longer in the ASR group compared with those in the control 2 cohort (P = .0201). There were no statistical differences in visual acuity. CONCLUSION: A statistically significant disturbance in visual electrophysiology was found in the ASR group when compared with the control groups. These differences did not translate to identifiable clinical visual deficits. Orthopedic surgeons need to be aware of the possibility of visual dysfunction in patients with ASR and other metal-on-metal hip arthroplasties; however, routine visual testing is not recommended.
引用
- Unsworth-Smith T, Khan JC, Khan RJK, et al. Impact of Raised Serum Cobalt Levels From Recalled Articular Surface Replacement Hip Prostheses on the Visual Pathway. J Arthroplasty. 2017. PMID: 28647139. doi:10.1016/j.arth.2017.04.064
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。